Fluke i430-Flexi-TF Instruction Sheet

Fluke i430-Flexi-TF Instruction Sheet

6000 a flexible ac current probe
Hide thumbs Also See for i430-Flexi-TF:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

LIMITED WARRANTY & LIMITATION OF LIABILITY
LIMITED WARRANTY & LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one year
and begins on the date of shipment. Parts, product repairs and services are
warranted for 90 days. This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and does not apply to
fuses, disposable batteries or to any product which, in Fluke's opinion, has
been misused, altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that software will operate
substantially in accordance with its functional specifications for 90 days and
that it has been properly recorded on non-defective media. Fluke does not
warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused
products to end-user customers only but have no authority to extend a greater or
different warranty on behalf of Fluke. Warranty support is available if product is
purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one
country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase
price, free of charge repair, or replacement of a defective product which is
returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center
or send the product, with a description of the difficulty, postage and insurance
prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke
assumes no risk for damage in transit. Following warranty repair, the product will
be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that the failure was caused by misuse, alteration, accident or
abnormal condition of operation or handling, Fluke will provide an estimate of
repair costs and obtain authorization before commencing the work. Following
repair, the product will be returned to the Buyer transportation prepaid and the
Buyer will be billed for the repair and return transportation charges (FOB
Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING
FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT,
RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not affect the validity or enforceability of
any other provision.
Fluke Corporation
P.O. Box 9090
Everett WA
98206-9090, USA
SERVICE CENTERS
To locate an authorized service center,
visit us on the World Wide Web:
http://www.fluke.com
or call Fluke using any of the phone numbers listed below:
+1-888-993-5853 in U.S.A. and Canada
+31-40-267-5200 in Europe
+1-425-446-5500 from other countries
Fluke i430 Flexi-TF Specs
Provided by www.AAATesters.com
Fluke Industrial B.V.
P.O. Box 90
7600 AB Almelo
The Netherlands
i430-Flexi-TF
6000 A Flexible AC Current Probe
Introducing the i430-Flexi-TF
The i430-Flexi-TF is a flexible AC current probe for use with the
Fluke 430 series Power Quality Analyzers including Series II. The
i430-Flexi-TF is optimized for current measurement on thick and
hard to reach conductors.
Unpacking
The following items should be included in the package:
• i430-Flexi-TF Current Probe(s)
• Instruction Sheet (this paper)
Check the contents of the shipping box for completeness. If
something in the box has been damaged or missing, contact your
distributor or the nearest FLUKE sales or service office immediately.
Safety Information
Read First: Safety Information
To ensure safe operation and service of the current
clamp, follow these instructions:
Read the operating instructions before use and follow all safety
instructions.
Use the Current Probe only as specified in the operating
instructions; otherwise the probe's safety features may not
protect you.
Adhere to local and national safety codes. Individual protective
equipment must be used to prevent shock and arc blast injury
where hazardous live conductors are exposed.
Before each use, inspect the Current Probe and its latching
system for any damage. Pay particular attention to the
insulation surrounding the flexible measuring head. Look for
cracks or missing portions of the probe housing or output cable
insulation. Also look for loose or weakened components.
Do not use a Current Probe that is cracked, damaged, or has a
defective cable.
Never use the probe on a circuit with voltages higher than
1000 V CAT III or 600V CAT IV
Measurement Category III refers to distribution level and fixed
installation circuits inside a building.
Measurement Category IV refers to the overhead or
underground utility service of an installation.
De-energize the installation on which current will be measured
or adopt safe operating procedures during application and
removal of the current probe.
Use extreme caution when working around bare conductors or
bus bars.
Do apply the Current Probe to bare conductors carrying a
voltage from 30 V up to 1000 V unless you are wearing
protective clothing suitable for high-voltage work. Contact with
the conductor could result in electric shock. Always use
appropriate equipment for personal protection.
Use caution when working with voltages above 60 V dc, 30 V ac
rms or 42 V ac peak. Such voltages pose a shock hazard.
December 2011
© 2011 Fluke Corporation.
All rights reserved.
Printed in the EU All product
names are trademarks of their
respective companies.
Instruction Sheet

Advertisement

Table of Contents
loading

Summary of Contents for Fluke i430-Flexi-TF

  • Page 1 LIMITED WARRANTY & LIMITATION OF LIABILITY LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are i430-Flexi-TF warranted for 90 days.
  • Page 2: Instrument Compatibility

    Inspect the cable between the flexible probe and the Power Quality Analyzer for any damage. Transducer diameter 7.5 mm (0.3 in) • Check if the i430-Flexi-TF is the selected current probe on the Minimum bending radius 38 mm (1.5 in) Power Quality Analyzer (Clamp i430-Flexi-TF). Cable length from 2.5 m (98.4 in)
  • Page 3: Consignes De Sécurité

    été acquis par l'intermédiaire d'un les mesures de courant sur des conducteurs épais et difficiles point de vente agréé par Fluke ou bien si l'acheteur a payé le prix d’accès. international applicable. Fluke se réserve le droit de facturer à l'acheteur les frais d'importation des pièces de réparation ou de remplacement si le produit...
  • Page 4: Spécifications

    Une i430-Flexi-TF sous garantie sera réparée ou ±1 prise ou 0.1 A (Utiliser la valeur la • 0.5 to 30 A remplacée (au choix de Fluke) dans les plus brefs délais et plus élevée) retournée gratuitement. rejet champ magnétique 40 dB (câble >...
  • Page 5 Endverbraucher verkaufte Produkte Kennenlernen des i430-Flexi-TF leisten, sind jedoch nicht dazu berechtigt, diese Garantie im Namen von Fluke zu verlängern, auszudehnen oder in irgendeiner anderen Weise abzuändern. Der Der i430-Flexi-TF ist ein für den Einsatz mit den Netz- und Erwerber hat das Recht aus der Garantie abgeleitete Unterstützungs-leistungen...
  • Page 6: Spezifikationen

    0,05% des Meßwerts /°C Temperaturkopefficient bei überprüft werden. Achten Sie dabei insbesondere auf die Isolierung, in die der Betriebstempratur flexible Meßfühler eingehüllt ist. Ein i430-Flexi-TF, der in den Bereich der Garantieleistung fällt, wird sofort ausgebessert oder ausgewechselt (nach ● A = 12.7 mm ±0.5% des Meßwerts...
  • Page 7 Fluke. Puede utilizar el servicio de garantía Introducción a la i430-Flexi-TF si el producto ha si do comprado en una oficina de ventas Fluke autorizada o si el Comprador ha pagado el importe de aplicación internacional. Fluke se La i430-Flexi-TF es una sonda amperimétrica flexible para CA, diseñada...
  • Page 8: Especificaciones

    No quitar de conductores VIVOS PELIGROSOS ni Compatibilidad del instrumento colocarlo a su alrededor. La i430-Flexi-TF sólo se puede utilizar con los analizadores trifásicos de calidad eléctrica Serie 433/434/435/437 de Fluke incluyendo Series II. El producto está protegido por aislamiento doble.
  • Page 9 I rivenditori autorizzati Fluke applicheranno la garanzia sui prodotti nuovi e non usati esclusivamente ai clienti finali, ma non potranno emettere una garanzia differente o più completa a nome di Fluke. La garanzia è valida se il prodotto è acquistato attraverso la rete commerciale Fluke o se l’acquirente ha pagato il prezzo applicabile a livello internazionale.
  • Page 10: Manutenzione

    Simbologia Compatibilità dello Strumento La sonda i430-Flexi-TF può essere utilizzata solo con gli analizzatori di rete Non applicare intorno a conduttori SOTTO TENSIONE serie Fluke 433/434/435/437 compresi Series II. PERICOLOSI o rimuovere dagli stessi. Impiego della sonda i430-Flexi-TF Prodotto protetto da isolamento doppio.

Table of Contents