Servicing The Battery - Toro Groundsmaster 4300-D Service Manual

Hide thumbs Also See for Groundsmaster 4300-D:
Table of Contents

Advertisement

Servicing the Battery

Removing and Installing the Battery
Electrical System: Service and Repairs
The battery is the heart of the electrical system. With the regular and correct
service, the battery life can be extended. Additionally, the battery and electrical
component failure can be prevented.
Battery-electrolyte is corrosive and can burn skin and eyes and
damage clothing.
While working with the batteries, use extreme caution to avoid
splashing or spilling of the electrolyte. Always wear the safety
goggles and a face shield while working with batteries.
Battery Specifications
Battery-electrolyte specific gravity
Battery specifications
Battery dimensions (including terminal posts
and caps)
g191002
1.
Cord grip locknut
2.
Negative cable
3.
Cord grip
4.
Positive cable
5.
Carriage screw
CAUTION
Fully Charged: 1.250 to 1.280
Discharged: less than 1.240
BCI Group Size: 55
585 CCA at -18°C (0°F)
Reserve Capacity of 75 minutes at 27°C (80°F)
Length 23.1 cm (9.1 inches)
Width 15.2 cm (6.0 inches)
Height 21.6 cm (8.5 inches)
Figure 200
6.
Battery mat
7.
Battery retainer
8.
Flange nut
9.
Battery
10.
Battery cover
Page 5–94
Groundsmaster
®
4300-D
16226SL Rev C

Advertisement

Table of Contents
loading

Table of Contents