Fujitsu Siemens Computers PRIMESTATION Series Manual page 86

As lan console or system management console (smc)
Table of Contents

Advertisement

RCA commands
Port Set
You can use the Port Set command to change the settings of the RCA ports. At
least one of the possible parameters must be specified.
The changes generally come into effect the next time a connection is set up via
this port.
Access rights:
SCON
Syntax:
port_number
PORT [<
[BAUD=<baud_rate>]
[SIZE=<size>]
[PARITY=<parity>]
[STOP=<stop_bits>]
[FLOW=<flow_control>]
[TIMEOUT=<timeout_seconds>]
[SOCKET=<telnet_socket_number>]
[CLI=<cli_value>]
Parameters:
port_number
Valid port numbers: 1-16 with RCA4 (16 ports), 1-8 with RCA4-8.
Where ALL is selected, the changes affect all RCA ports.
Default: The port to which the user is connected, if access to the
CLI was requested from an active console connection.
baud_rate
Line speed in baud:
9600, 19200
Default: 9600
size
Number of data bits per character: 7 or 8
Default: 8
80
PRIMESTATION as LAN Console
>|ALL] SET
U41270-J-Z916-2-76