Tews Technologies TVME201 User Manual

4 slot industrypack vmebus carrier

Advertisement

Quick Links

The Embedded I/O Company
4 Slot IndustryPack® VMEbus Carrier
TVME201
Version 1.1
User Manual
Issue 1.1.1
January 2018
TEWS TECHNOLOGIES GmbH
Am Bahnhof 7
Phone: +49 (0) 4101 4058 0
e-mail:
info@tews.com
25469 Halstenbek, Germany
Fax: +49 (0) 4101 4058 19
www.tews.com

Advertisement

Table of Contents
loading

Summary of Contents for Tews Technologies TVME201

  • Page 1 The Embedded I/O Company TVME201 4 Slot IndustryPack® VMEbus Carrier Version 1.1 User Manual Issue 1.1.1 January 2018 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058 0 Fax: +49 (0) 4101 4058 19 e-mail: info@tews.com...
  • Page 2 However TEWS TECHNOLOGIES GmbH reserves the right to change the product described in this document at any time without notice. TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein.
  • Page 3 Function added to switch S3 September 2004 Clarification of Interrupt Mapping November 2004 New address TEWS LLC September 2006 1.1.0 new User Manual Issue Notation December 2008 1.1.1 General Revision January 2018 TVME201 User Manual Issue1.1.1 Page 3 of 26...
  • Page 4: Table Of Contents

    7.2 Fuses and Filters ........................... 23 PIN ASSIGNMENT ....................24 8.1 IP Connectors ..........................24 8.2 VMEbus Connectors ........................25 8.2.1 VMEbus P1 Connectors ....................25 8.2.2 VMEbus P2 Connector ..................... 26 TVME201 User Manual Issue1.1.1 Page 4 of 26...
  • Page 5 FIGURE 3-4 : VME A24/A32 MEMORY ENABLE AND SIZE ................. 13 FIGURE 3-5 : VME A24/A32 BASE ADDRESS ....................14 FIGURE 5-1 : IP STROBE SIGNAL ........................ 21 FIGURE 6-1 : FRONT PANEL......................... 22 TVME201 User Manual Issue1.1.1 Page 5 of 26...
  • Page 6 TABLE 7-2 : IP POWER LED .......................... 23 TABLE 8-1 : IP J1 LOGIC INTERFACE PIN ASSIGNMENT ................24 TABLE 8-2 : VMEBUS P1 CONNECTOR ....................... 25 TABLE 8-3 : VMEBUS P2 CONNECTOR ....................... 26 TVME201 User Manual Issue1.1.1 Page 6 of 26...
  • Page 7: Product Description

    VME A32 space, there is a fixed space of 8 Mbytes for each IP module. Strobe signals of all IP modules are accessible via a 4 pin jumper block on the TVME201. DMA, 32 bit access and 32 MHz operations are not supported.
  • Page 8: Technical Specification

    Notice 2 formulas are used for FIT rate calculation. Weight 260 g – no IndustryPack inserted Size Singe Size 6U Euro Card Humidity 5 – 95 % non-condensing Table 2-1 : Technical Specification TVME201 User Manual Issue1.1.1 Page 8 of 26...
  • Page 9: Configuration

    3 Configuration Setting 6 rotary switches allows all required configuration of the TVME201. Position of the switches is shown below: Figure 3-1 : Rotary Switch S1 – S6 Step Rotary Switch Function Default Value S1 / S2 VME A16 Base Address...
  • Page 10: Vme A16 Base Address

    Register depends on the position of switch S3: With S3 = “0” to “7”, the IP IRQ and Control Registers of the TVME201 are accessible, and the size of the IP ID space is 64 bytes. The remaining 64 bytes are occupied by the IP IRQ and Control Registers.
  • Page 11: Table 3-2 : Vme A16 Address Map (S3 = "0" To "7")

    + 0x0280 ID Space IP C 0x6280 + 0x0300 I/O Space IP D 0x6300 + 0x0380 ID Space IP D 0x6380 Table 3-3 : VME A16 Address Map (S3 = “8” to “F”) TVME201 User Manual Issue1.1.1 Page 11 of 26...
  • Page 12: Interrupts

    “0” to “7” is mirrored at S3 = “8” to “F”. The difference is that access to the IP IRQ and Control Registers of the TVME201 is only possible in switch position S3 = “0” to “7”. See Chapter “IP IRQ and Control Register”...
  • Page 13: Vme A24/A32 Memory Enable And Size

    IP requires 64 Kbytes of memory and 2 IP require no memory, then S4 must be set to “3”, which selects a VME A24 memory size of 512 Kbytes, 128 Kbytes memory for each TVME201 User Manual Issue1.1.1 Page 13 of 26...
  • Page 14: Vme A24/A32 Base Address

    The memory space of IndustryPacks is mapped in the VME A24 or VME A32 space. The memory base address for VME A24 or VME A32 is both set with the switches S5 and S6. Figure 3-5 : VME A24/A32 Base Address TVME201 User Manual Issue1.1.1 Page 14 of 26...
  • Page 15 If memory space is located in VME A24, S5 represents A[23:20], and S6 represents A[19:16]. In VME A32, S5 represents [A31:28] and S6 represents A[27:24]. The memory base address of the TVME201 must be set on a boundary equal to the memory size, as selected by S4! See figure below for details.
  • Page 16: Table 3-6 : Vme A24/A32 Address Map

    0x800000 2 Mbytes 0x400000 2 Mbytes 0x600000 8 Mbytes 0x00000000 8 Mbytes 0x00800000 32 Mbytes multiple of 0x02000000 8 Mbytes 0x01000000 8 Mbytes 0x01800000 Table 3-6 : VME A24/A32 Address Map TVME201 User Manual Issue1.1.1 Page 16 of 26...
  • Page 17: Ip Irq And Control Register

    4 IP IRQ and Control Register If switch S3 is in the range of “0” to “7”, the TVME201 provides a set of two registers for each IP: The IP IRQ Configuration Register and the IP Control Register. Setting switch S3 to a value of “8” to “F” disables the IP IRQ Register and the IP Control Register. The address range of the IP IRQ and Control Register from “VME A16 Base Address”...
  • Page 18: Table 4-2 : Ip Irq Configuration Registers (Ip C / Ip D)

    S3 jumper 000 = interrupt is disabled IPD, INT0 setting [2:0] 001 to 111 = VMEbus IRQ-levels IRQ1 to IRQ7 Table 4-2 : IP IRQ Configuration Registers (IP C / IP D) TVME201 User Manual Issue1.1.1 Page 18 of 26...
  • Page 19: Control Register

    1 = error signal is active IP B, INT1 Interrupt status 1 = indicates a pending interrupt request IP B, INT0 Table 4-3 : IP Control Registers (IP A / IP B) TVME201 User Manual Issue1.1.1 Page 19 of 26...
  • Page 20: Table 4-4 : Ip Control Registers (Ip C / Ip D)

    1 = error signal is active IP D, INT1 Interrupt status 1 = indicates a pending interrupt request IP D, INT0 Table 4-4 : IP Control Registers (IP C / IP D) TVME201 User Manual Issue1.1.1 Page 20 of 26...
  • Page 21: Ip Strobe Signal

    IP module. It is reserved for a digital strobe or clock signal related to the functionality of the IP. Strobe signals of each of the four IP slots are accessible on the TVME201 via a 4 pin jumper field. Figure 5-1 : IP Strobe Signal TVME201 User Manual Issue1.1.1...
  • Page 22: Installation Of Industrypacks

    After an IP has been installed it can be secured on the carrier board. This is normally necessary only in high vibration or shock environments. Screws and spacers are required to fix a single IP on the TVME201. They can be ordered from TEWS TECHNOLOGIES GmbH (Part number: TIPxxx-HK).
  • Page 23: Front Panel Indicators

    7.1 ACK and Power LEDs For a quick visual inspection the TVME201 offers a total of 10 LEDs in the front panel. Each IndustryPack has its own “ACK” LED, which is lit for about 200ms whenever an access to the corresponding IP happens.
  • Page 24: Pin Assignment

    8 Pin Assignment 8.1 IP Connectors The table below shows the complete IP J1 logic interface pin assignments. Some of these signals are not used on the TVME201. Pin # Signal Pin # Signal Pin # Signal Pin # Signal...
  • Page 25: Vmebus Connectors

    VME_A16 VME_AM4 VME_A15 VME_A7 VME_IRQ7# VME_A14 VME_A6 VME_IRQ6# VME_A13 VME_A5 VME_IRQ5# VME_A12 VME_A4 VME_IRQ4# VME_A11 VME_A3 VME_IRQ3# VME_A10 VME_A2 VME_IRQ2# VME_A9 VME_A1 VME_IRQ1# VME_A8 -12V +12V Table 8-2 : VMEbus P1 Connector TVME201 User Manual Issue1.1.1 Page 25 of 26...
  • Page 26: Vmebus P2 Connector

    8.2.2 VMEbus P2 Connector Row A Row B Row C VME_A24 VME_A25 VME_A26 VME_A27 VME_A28 VME_A29 VME_A30 VME_A31 Table 8-3 : VMEbus P2 Connector TVME201 User Manual Issue1.1.1 Page 26 of 26...