The Embedded I/O Company TVME201 4 Slot IndustryPack® VMEbus Carrier Version 1.1 User Manual Issue 1.1.1 January 2018 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058 0 Fax: +49 (0) 4101 4058 19 e-mail: info@tews.com...
Page 2
However TEWS TECHNOLOGIES GmbH reserves the right to change the product described in this document at any time without notice. TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein.
Page 3
Function added to switch S3 September 2004 Clarification of Interrupt Mapping November 2004 New address TEWS LLC September 2006 1.1.0 new User Manual Issue Notation December 2008 1.1.1 General Revision January 2018 TVME201 User Manual Issue1.1.1 Page 3 of 26...
VME A32 space, there is a fixed space of 8 Mbytes for each IP module. Strobe signals of all IP modules are accessible via a 4 pin jumper block on the TVME201. DMA, 32 bit access and 32 MHz operations are not supported.
Notice 2 formulas are used for FIT rate calculation. Weight 260 g – no IndustryPack inserted Size Singe Size 6U Euro Card Humidity 5 – 95 % non-condensing Table 2-1 : Technical Specification TVME201 User Manual Issue1.1.1 Page 8 of 26...
3 Configuration Setting 6 rotary switches allows all required configuration of the TVME201. Position of the switches is shown below: Figure 3-1 : Rotary Switch S1 – S6 Step Rotary Switch Function Default Value S1 / S2 VME A16 Base Address...
Register depends on the position of switch S3: With S3 = “0” to “7”, the IP IRQ and Control Registers of the TVME201 are accessible, and the size of the IP ID space is 64 bytes. The remaining 64 bytes are occupied by the IP IRQ and Control Registers.
+ 0x0280 ID Space IP C 0x6280 + 0x0300 I/O Space IP D 0x6300 + 0x0380 ID Space IP D 0x6380 Table 3-3 : VME A16 Address Map (S3 = “8” to “F”) TVME201 User Manual Issue1.1.1 Page 11 of 26...
“0” to “7” is mirrored at S3 = “8” to “F”. The difference is that access to the IP IRQ and Control Registers of the TVME201 is only possible in switch position S3 = “0” to “7”. See Chapter “IP IRQ and Control Register”...
IP requires 64 Kbytes of memory and 2 IP require no memory, then S4 must be set to “3”, which selects a VME A24 memory size of 512 Kbytes, 128 Kbytes memory for each TVME201 User Manual Issue1.1.1 Page 13 of 26...
The memory space of IndustryPacks is mapped in the VME A24 or VME A32 space. The memory base address for VME A24 or VME A32 is both set with the switches S5 and S6. Figure 3-5 : VME A24/A32 Base Address TVME201 User Manual Issue1.1.1 Page 14 of 26...
Page 15
If memory space is located in VME A24, S5 represents A[23:20], and S6 represents A[19:16]. In VME A32, S5 represents [A31:28] and S6 represents A[27:24]. The memory base address of the TVME201 must be set on a boundary equal to the memory size, as selected by S4! See figure below for details.
4 IP IRQ and Control Register If switch S3 is in the range of “0” to “7”, the TVME201 provides a set of two registers for each IP: The IP IRQ Configuration Register and the IP Control Register. Setting switch S3 to a value of “8” to “F” disables the IP IRQ Register and the IP Control Register. The address range of the IP IRQ and Control Register from “VME A16 Base Address”...
S3 jumper 000 = interrupt is disabled IPD, INT0 setting [2:0] 001 to 111 = VMEbus IRQ-levels IRQ1 to IRQ7 Table 4-2 : IP IRQ Configuration Registers (IP C / IP D) TVME201 User Manual Issue1.1.1 Page 18 of 26...
1 = error signal is active IP B, INT1 Interrupt status 1 = indicates a pending interrupt request IP B, INT0 Table 4-3 : IP Control Registers (IP A / IP B) TVME201 User Manual Issue1.1.1 Page 19 of 26...
1 = error signal is active IP D, INT1 Interrupt status 1 = indicates a pending interrupt request IP D, INT0 Table 4-4 : IP Control Registers (IP C / IP D) TVME201 User Manual Issue1.1.1 Page 20 of 26...
IP module. It is reserved for a digital strobe or clock signal related to the functionality of the IP. Strobe signals of each of the four IP slots are accessible on the TVME201 via a 4 pin jumper field. Figure 5-1 : IP Strobe Signal TVME201 User Manual Issue1.1.1...
After an IP has been installed it can be secured on the carrier board. This is normally necessary only in high vibration or shock environments. Screws and spacers are required to fix a single IP on the TVME201. They can be ordered from TEWS TECHNOLOGIES GmbH (Part number: TIPxxx-HK).
7.1 ACK and Power LEDs For a quick visual inspection the TVME201 offers a total of 10 LEDs in the front panel. Each IndustryPack has its own “ACK” LED, which is lit for about 200ms whenever an access to the corresponding IP happens.
8 Pin Assignment 8.1 IP Connectors The table below shows the complete IP J1 logic interface pin assignments. Some of these signals are not used on the TVME201. Pin # Signal Pin # Signal Pin # Signal Pin # Signal...