LuminAir Turbo Fan & Light Ventilation Kits Installation and Wiring Instructions Stock Ref. N° LuminAir Turbo SKL 453419C LuminAir Turbo SKT 453422C Kit comprises of:- Luminair turbo L or T mains fan SELV light assembly with white bezel Lighting transformer 90°...
Page 2
C.Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D.The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. It is recommended that the connection to the fan connecter terminals is made with flexible cable.
Page 3
A. INSTALLATION. The LuminAir Turbo kit is designed where a more powerful system is required. The kit comprises of a LuminAir Turbo L or T mains fan, SELV light assembly and transformer, a white bezel, 90 deg bend, 6 metres of flexible duct, quick fix wall grille and 4 duct ties.
Page 4
Make the appropriate electrical connections to the Turbo fan as shown in Figs 10 or 11 (See section B Wiring) From the outside cut a 110mm hole in the soffit and secure the soffit grille using the screws provided. Extend the ductwork provided between the soffit grille and the outlet of the turbo fan again securing with the duct ties provided.
Page 5
11 – LuminAir Turbo SKT 453422B (With Timer) TIMER ADJUSTMENT (LuminAir Turbo SKT 453422C only) The fan must be wired to a remote switch (e.g. light switch). When switched ‘ON’, the fan will operate at the selected speed, and will continue to run for a preset time after the fan Timer adjuster is switched ‘OFF’.
Page 6
C. OVER-HEATING PROTECTION. The fan motor is fitted with Thermal Overload Protection. This is a one-shot thermal fuse. In the event of a fault condition the fan will be automatically switched off. If this occurs isolate the fan, and call your service engineer. D.
Page 7
PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent‐Axia Vent‐Axia LuminAir Turbo SKL ‐ LuminAir Turbo SKT ‐ Model ID (Stock Ref.) : 453419C 453422C SEC Class E E SEC Value ('Average') 17.15 18.74 SEC Value ('Warm') 7.76 8.48 SEC Value ('Cold') 33.55 36.67 Label Required? (Yes/No=Out of scope) No No Declared as: RVU or NRVU/UVU or BVU RVU‐UVU RVU‐UVU Speed Drive on/off Single Speed ...
Page 8
Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- ...