Rise or Fall Time
Transition Time, 0 %-Level and 100 %-Level Readout (Manual or Auto Leveling; Auto Leveling only possible in Single Channel Mode)
Accuracy
As Oscilloscope Accuracy

Recorder

The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The
information is stored on internal memory or on optional SD card with the 125B or 124B.
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a
waveform recorder display that plots all the captured samples.
Meter Readings
Measurement Speed ........................................... maximum 2 measurements/s
Record Size ......................................................... 2 M readings for 1 channel (400 MB)
Recorded Time Span .......................................... 2 weeks
Maximum number of events ................................ 1024
Waveform record
Maximum sample rate ......................................... 400 K sample/s
Record Size Internal memory .............................. 400 M samples
Recorded Time Span internal memory ............... 15 minutes at 500 μs/div
125B, 124B
Record Size SD card................................... 15 G samples
Recorded Time Span SD card .................... 11 hours at 500 μs/div
Maximum number of events ................................ 64 events on 1 channel
11 hours at 20 ms/div
14 days at 20 ms/div