Model
Maximum
Total
No.
Input
Resistance
Voltage
BOA-1
1 KV
lM
BOA-2
2 KV
2M
BOB-5
5 KV
5M
BOB-10
10 KV
lOM
BOC-15
15 KV
15 M
BOC-20
20 KV
20 M
BOC-25
25 KV
25 M
BOC-30
30 KV
30 M
MODELS
SIZE
BOA
6-3/4" high
5-1/ 4" wide
2:..1/4" deep
BOB
10-9/32" high
B" wide
10" deep
BOC
13" high
9-3/4 " wide
16" deep
Current
Division Ratio
Division
Stability of
Temp. Coef.
Drawn At
Division
of
500
v
lV
Accuracy
Accuracy
Max. Input
Out
Out
Per Year
Division Ratio
1 ma
2:1
- -
±0. 015%
- -
- -
4:1
- -
1 ma
10:1
5, 000:1
±0. 01%
±0. 005%
±0. 005%/0C
20:1
10, 000:1
from ooc to 600C
30:1
15,000:1
1 ma
40:1
20, 000:1
±0. 01%
±0. 0005%
±0. 00023; 0 c
50:1
25, 000:1
from ooc to 35oc
60:1
30, 000:1
INPUT
OUTPUT
CONNECTOR
CONNECTOR
UG- 560U with mating connector
Insulated binding posts on 3/4"
supplied
centers
AN3102-1B-165 with mating
Insulated binding posts on 3/4"
connector supplied
centers for both outputs
Special 5" ceramic standoff with
Insulated binding post on 3/4"
mating B" polystyrene connector
centers for both outputs
supplied
6-2.
POTENTIOMETRIC RECORDER
The Fluke Model A-70 Self Balancing Potentiometric Re-
corder is a special purpose high sensitivity recorder de-
veloped for monitoring voltages measured by the
W
BOO
Series Differential Voltmeters. In addition to providing a
permanent record of results, the recorder allows
un-
attended monitoring of various voltages from 0 to 500
volts for long periods of time. A sample voltage which
varies in direct proportion to the source under measure-
ment is obtained from the voltmeter null detector by
connecting the recorder to the output terminals at the
rear of the voltmeter. A gain adjustment control adjacent
to the voltmeter output terminals allows the sample vol-
tage to be adjusted such that full-scale meter deflection
equals full-scale recorder deflection. The large leakage
resistance (500, 000 megohms} between the recorder in-
put posts and chassis is such that the inherently high
accuracy of the Fluke Differential Voltmeter is generally
not impaired in any way.
Electrical Span:
10
mv DC
Span Step Response Time:
Less than 0. 5 seconds
Accuracy:
0. 5% of span
Chart Speeds:
0. 75, 1. 5, 3. 6, or
12 in. /min. or in. /hr.
MODEL A-70 POTENTIOMETRIC RECORDER
Dimensions:
Cabinet Model -
6-2
Cabinet Model--9-1/4" high, B-1/4" wide, 15" deep.
Rack Model--Available on special request.