Rheem RIWH09AVFJ Design & Technical Manual page 102

Multi: 5 rooms type
Hide thumbs Also See for RIWH09AVFJ:
Table of Contents

Advertisement

Indoor unit connect-
Outdoor temperature
ing capacity
kBtu/h
°FDB
14
23
32
41
50
59
34
67
77
87
95
104
115
NOTE: Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 2 or more indoor units should be connected.
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor
unit]
• The total ability of connected a indoor unit is from 34,000 Btu up to 54,000 Btu.
• Input in the table are calculated based on the maximum indoor unit input combi-
nations.
64 °FDB
70 °FDB
54 °FWB
60 °FWB
TC
IP
TC
IP
28.4
1.01
32.1
1.02
28.4
1.05
32.1
1.07
28.4
1.10
32.1
1.12
28.4
1.22
32.1
1.25
28.4
1.35
32.1
1.37
28.4
1.86
32.1
1.89
28.4
2.37
32.1
2.41
28.4
2.61
32.1
2.65
28.4
2.85
32.1
2.90
28.4
3.04
32.1
3.09
24.7
2.82
28.0
2.87
24.7
2.61
28.0
2.65
- 96 -
Indoor temperature
75 °FDB
80 °FDB
63 °FWB
67 °FWB
TC
IP
TC
IP
33.9
1.03
36.3
1.04
33.9
1.08
36.3
1.09
33.9
1.13
36.3
1.14
33.9
1.26
36.3
1.27
33.9
1.39
36.3
1.40
33.9
1.91
36.3
1.93
33.9
2.43
36.3
2.45
33.9
2.67
36.3
2.70
33.9
2.92
36.3
2.95
33.9
3.12
36.3
3.15
29.5
2.90
31.5
2.93
29.5
2.67
31.5
2.70
85 °FDB
90 °FDB
71 °FWB
73 °FWB
TC
IP
TC
IP
38.8
1.06
40.0
1.06
38.8
1.10
40.0
1.11
38.8
1.15
40.0
1.16
38.8
1.28
40.0
1.29
38.8
1.42
40.0
1.42
38.8
1.95
40.0
1.96
38.8
2.48
40.0
2.50
38.8
2.74
40.0
2.75
38.8
2.99
40.0
3.00
38.8
3.19
40.0
3.21
33.7
2.96
34.8
2.98
33.7
2.73
34.8
2.75