8.4 Menu overview

"Home"
Status
Control mode
Operating status
Setpoint
Operating mode, from
Estimated flow
Control mode
1), 2)
Low flow
Pump performance
Head
Max. curve and duty point
Resulting setpoint
Temperature
Speed
Operating hours
Power and energy consumption
Power consumption
Energy consumpt.
Warning and alarm
Actual warning or alarm
Warning log
Alarm log
Heat energy monitor
Heat power
Heat energy
Estimated flow
Volume
Hours counter
Temperature 1
Temperature 2
Differential temp.
Accuracy of values
Operating log
Operating hours
Trend data
Fitted modules
Date and time
Date
Time
Pump identification
Multipump system
Operating status
System performance
Power and energy consumption
Other pump, multipump system
36
Warning log 1 to 5
Alarm log 1 to 5
Estimated flow
Volume
Duty point over time
3D showing (Q, H, t)
3D showing (Q, T, t)
3D showing (Q, P, t)
3D showing (T, P, t)
Operating mode, from
Control mode
Duty point
Resulting setpoint
System identification
Power consumption
Energy consumpt.
Operating mode, from
Speed
Operating hours
Pump identification
Power consumption
"Settings"
Setpoint
Operating mode
Normal
Stop
Min.
Max.
Control mode
AUTO
ADAPT
FLOW
ADAPT
Prop. press.
Const. press.
Const. temp.
Diff. temp.
1)
Constant flow
Constant curve
Controller settings (not model A)
Controller gain Kp
Control. integr. action time Ti
1)
Temperature sensor offset
FLOW
LIMIT
Enable FLOWLIMIT function
Not active
Active
Set FLOWLIMIT
Automatic Night Setback
Not active
Active
Analog Input
Function of analog input
Not active
Differential-pressure control
Constant-temperature control
Differential-temperature control
Heat energy monitor
External setpoint influence
Unit
°C
°F
Sensor range, min. value
Sensor range, max. value
Electrical signal
0-10 V
4-20 mA
Relay outputs
Relay output 1
Not active
Ready
Alarm
Operation
Relay output 2
Not active
Ready
Alarm
Operation
Setpoint influence
External setpoint function
Not active
Linear with Min.
1)
Linear with Stop
Temperature influence
"Assist"
1)
Application wizard
Boiler pump
Radiator
Fan coil unit
Air handling unit
Underfloor/ceiling
Hot water
Ground source
Chiller pump
Setting of date and time
Date format, date and time
Date only
Time only
Multipump setup
Setup, analog input
Description of control mode
AUTO
ADAPT
FLOW
ADAPT
Prop. press.
Const. press.
Const. temp.
Differential temp.
Constant curve
Assisted fault advice
Blocked pump
Pump communication fault
Internal fault
Internal sensor fault
Forced pumping
Undervoltage
Overvoltage
High motor temperature
External sensor fault
High liquid temperature
Comm. fault, twin-head pump