12. Installation Instruction

12.1 Select the Best Location

12.1.1
Indoor Unit
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Indoor unit of this air conditioner shall be installed
in a height of at least 1.8 m.
12.1.2
Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Table A
Piping size
Capacity
Std.
Max.
Model
W
Length
Elevation
(HP)
(m)
(m)
Gas
Liquid
PZ25***,
UZ25***,
1.0HP
DZ25***
PZ35***,
9.52mm
6.35mm
UZ35***,
1
5 .
H
P
5
(3/8")
(1/4")
DZ35***
PZ50***,
UZ50***,
2
0 .
H
P
DZ50***
(*) Systems with total refrigerant charge, m
than 1.84kg are not subjected to any room area
requirements.
Example: For PZ25***
If the unit is installed at 10 m distance, the quantity of
additional refrigerant should be 25 g .... (10-7.5) m x
10 g/m = 25 g.
A
= (m
/ (2.5 x (LFL)
min
c
safety factor margin
A
= Required minimum room area, in m
min
m
= Refrigerant charge amount in appliance, in kg
c
LFL = Lower flammability limit (0.307 kg/m
h
= Installation height of the appliance (1.8 m for
0
wall mounted)
SF = Safety factor with a value of 0.75
Piping
Min.
Max.
Max.
Additional
Length
Piping
Piping
Refrigerant
Refrigerant
for add.
Length
Length
Charge
(g/m)
gas
(m)
(m)
(kg)
(m)
15
3
15
10
7.5
0.66
5 1
3
5 1
0 1
7
5 .
. 0
5 7
5 1
3
5 1
5 1
7
5 .
. 1
5 2
, lower
c
(5/4)
2
x h
))
** not less than
0
2
3
)
** The required minimum room area, A
be governed by the safety factor margin formula
below :
A
= m
min
The higher value shall be taken when determining the
room area.
12.1.3
Piping direction
Right
Right
Rear
50 mm
or more
Insulation of piping connections
Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to the wall
Remote control holder fixing screws 6
Indoor A
(m²)
min
Remote
control 3
Not applicable (*)
N
o
a t
p p
c i l
b a
e l
) * (
N
o
a t
p p
c i l
b a
e l
) * (
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
51
/ (SF x LFL x h
)
c
0
Indoor/Outdoor Unit Installation
Diagram
Attention not to bend
up drain hose
(Front side)
Right
Left
Left
bottom
Rear
Left bottom
(Left and right are identical)
Vinyl tape
Remote control holder 5
It is advisable to
avoid more than 2
blockage directions.
For better ventilation
& multiple-outdoor
installation, please
consult authorized
dealer/specialist.
, shall also
min
Installation parts you
should purchase ( )
Installation plate 1
Bushing-Sleeve ( )
Sleeve ( )
Putty ( )
(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Power supply cord ( )
Flare connection
Vinyl tape (wide) ( )
• Apply after carrying out
a drainage test.
• To carry out the
drainage test, remove
the air filters and pour
water into the heat
exchanger.
Saddle ( )
Connection cable
Liquid side piping ( )
Gas side piping ( )
Additional drain hose ( )