Panasonic CS-DZ50VKE Service Manual page 91

Hide thumbs Also See for CS-DZ50VKE:
Table of Contents

Advertisement

15.1.4
Compressor Overheating Prevention Control
Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The
changes of frequency are as below.
If compressor discharge temperature exceeds 103°C, compressor will be stopped, occurs 4 times per 20 minutes,
timer LED will be blinking. ("F97" is indicated.)
15.1.5
Low Pressure Prevention Control (Gas Leakage Detection)
Control start conditions
For 5 minutes, the compressor continuously operates and outdoor total current is between 1.22A and 1.38 A
o
(DZ/PZ/UZ25/35VK), between 0.75A and 0.95A (DZ/PZ/UZ50VK).
During Cooling and Soft Dry operations:
o
Indoor suction temperature - indoor piping temperature is below 4°C.
During Heating operations :
o
Indoor piping temperature - indoor suction is under 5°C.
Control contents
Compressor stops (and restart after 3 minutes).
o
If the conditions above happen 2 times within 20 minutes, the unit will:
o
Stop operation
Timer LED blinks and "F91" indicated.
15.1.6
Low Frequency Protection Control 1
When the compressor operate at frequency lower than 24 Hz continued for 20 minutes, the operation frequency
will be changed to 23 Hz for 2 minutes.
15.1.7
Low Frequency Protection Control 2
When all the below conditions comply, the compressor frequency will change to lower frequency.
Indoor intake air (°C)
Outdoor air (°C)
Indoor heat exchanger (°C)
Fre quency
103°C
99°C
96°C
Comp temp
Temperature, T, for:
Compressor =
OFF
Compressor Frequency
Reduce
Compressor Frequency
Limited
Free
Cooling/Soft Dry
T < 14 or T ≥ 30
T < 13 or T ≥ 38
T < 30
91
88°C
87°C
86°C
Heating
T < 14 or T ≥ 28
T < 4 or T ≥ 24
T ≥ 0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents