19. Push the holdfast to the left and lift up the evaporator.
Evaporator
Cross Flow Fan
20. Remove the cross flow fan from
the unit by pulling it to the left and
downward.
Figure 10
Figure 11
137
21. Fan motor can be removed after the
removal of cross flow fan.
Reminder: To reinstall the fan motor, adjust
the fan motor connector to 45° towards you
before fixing control board.
Reminder: To reinstall the cross flow
fan, please ensure cross flow fan is
in line as shown in figure 11.