Panasonic CS-DZ50VKE Service Manual page 56

Hide thumbs Also See for CS-DZ50VKE:
Table of Contents

Advertisement

Recommended
length (mm)
WARNING
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
12.2.4.1
Wire Stripping and Connecting Requirement
Wire stripping
No loose strand
when inserted
Indoor/outdoor
connection
terminal board
5 mm or more
(gap between wires)
Conductor
Conductor over
fully inserted
inserted
ACCEPT
PROHIBITED
a
b
c
d
e
f
55 35 35 50 40 35 60
Recommended
length (mm)
Power
supply
cord
WARNING
Do not joint wires
Conductor not
fully inserted
PROHIBITED
Terminal Board
g
Earth Wire
longer
than
others
AC wires
for safety
reason
Holder
Power supply
Tape
cord
Isolating Devices
RISK OF FIRE
JOINING OF WIRES MAY
CAUSE OVERHEATING
AND FIRE.
OR
56
Control
Board
Earth Wire
longer than
others AC
wires for
safety reason
Holder
Indoor & outdoor
connection cable
Outdoor unit
Connection cable
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
wiring rules.
Tape
OR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents