Cooling
Dry
Heating
1
Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner
is stopped using remote control, the vane will shift to close position.
2
Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above
and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control,
the vane will shift to close position.
14.4.2
Horizontal Airflow
The horizontal airflow direction louver can be adjusted manually by hand.
Operation Mode
Usual (Ventilation)
Auto
Control with dew
Usual (Ventilation)
Manual
Control with dew
Usual
Auto
Control with dew
Usual
Manual
Control with dew
Manual
Usual
A
Auto
B
C
CS-DZ/PZ/UZ50VK
Vane Angle (°)
1
2
3
5 ~ 35
5 ~ 35
5
12.5
20
5
12.5
20
5 ~ 35
5 ~ 35
5
12.5
20
5
12.5
20
5
17.5
30
5
42.5
17.5
85
4
5
27.5
35
27.5
35
27.5
35
27.5
35
42.5
55

Hide quick links: