Device Management

This section describes how to connect to and manage the device.
CONTENTS
Section 3.1, "Connecting to the Device"
Section 3.2, "Configuring the Device"
Section 3.1

Connecting to the Device

The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces
on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM
RS910W.
IMPORTANT!
Ethernet cables should be only be connected/disconnected in a non-hazardous area, or when the
device is not energized.
Console Port
Connect a workstation directly to the RS232 serial console port to access the boot-time control and RUGGEDCOM
ROS console interface. The console port provides access to RUGGEDCOM ROS's console interface.
IMPORTANT!
The serial console port is intended to be used only as a temporary connection during initial
configuration or troubleshooting, and should only be used in a safe area (as defined by IEC 60079-0,
Edition 6.0).
Use the following settings to connect to the port:
Speed
Data Bits
Stop Bit
Parity
Flow Control
Terminal ID
The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The
following is the pin-out for the port:
Connecting to the Device
57600 baud
8
1
None
Off
VT100
Chapter 3
Device Management
19