Mounting The Device - Siemens RUGGEDCOM RS910W Installation Manual

Hide thumbs Also See for RUGGEDCOM RS910W:
Table of Contents

Advertisement

RUGGEDCOM RS910W
Installation Guide
• The console port should only be used in the safe area.
• The equipment should be appropriately connected to safety Earth upon installation.
NOTE
For further details of the device's compliance with Class I, Division 2 standards, refer to
"Approvals".
IMPORTANT!
Do not disconnect or open equipment unless power has been switched off or the area is known to be
non-hazardous.
IMPORTANT !
Débrancher ou ouvrir l'équipment seulement si l'alimnetation a été coupée ou si l'on sait que la zone
ne pose aucun danger.
IMPORTANT!
Substitution of the components may impair suitability for Class I, Division 2.
IMPORTANT !
Le remplacement de composants pourrait compromettre l'admissibilité à la Classe I, Division 2.
Section 2.4

Mounting the Device

The RUGGEDCOM RS910W is designed for maximum mounting and display flexibility. It can be equipped with
adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.
IMPORTANT!
Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended
that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some
convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to
Section 5.8, "Dimension
CONTENTS
Section 2.4.1, "Mounting the Device on a DIN Rail"
Section 2.4.2, "Mounting the Device to a Panel"
Mounting the Device
Drawings".
Chapter 2
Installing the Device
Section 6.1,
9

Advertisement

Table of Contents
loading

Table of Contents