100
(0.7, 7)
80
(0.55, 5.5)
60
(0.41, 4.1)
40
(0.28, 2.8)
20
(0.14, 1.4)
0
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid
flow (gpm/lpm) and operating air pressure (psi/MPa/bar):
1.
Locate fluid flow rate along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid
outlet pressure curve.
3.
Follow left to scale to read fluid outlet pressure.

Performance Charts

Fluid Outlet Pressure
Test Conditions: Pump tested in water with fluid inlet submerged
and air inlet restrictor removed. For performance with air inlet
restrictor in place, see manual 308589.
A
B
C
0
2
4
(7.6)
(15.2)
Fluid Pressure Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
A
at 70 psi (0.48 MPa, 4.8 bar) air pressure
B
at 40 psi (0.28 MPa, 2.8 bar) air pressure
C
6
8
10
(22.7)
(30.3)
(37.9)
FLUID FLOW – gpm (lpm)
12
14
16
(45.4)
(53.0)
(60.6)
308573