Graco Husky 716 Instructions-Parts List Manual page 26

Aluminum air-operated diaphragm pump
Hide thumbs Also See for Husky 716:
Table of Contents

Advertisement

30
(0.84)
25
(0.70)
20
(0.56)
15
(0.42)
10
(0.28)
5
(0.14)
0
0
To find Pump Air Consumption (scfm or m#/min) at a specific
fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):
1.
Locate fluid flow rate along bottom of chart.
2.
Read vertical line up to intersection with selected air
consumption curve.
3.
Follow left to scale to read air consumption.
26
308573
Performance Charts
Air Consumption
Test Conditions: Pump tested in water with fluid inlet submerged
and air inlet restrictor removed. For performance with air inlet
restrictor in place, see manual 308589.
Air Consumption Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
A
at 70 psi (0.48 MPa, 4.8 bar) air pressure
B
at 40 psi (0.28 MPa, 2.8 bar) air pressure
C
2
4
(7.6)
(15.2)
6
8
10
(37.9)
(22.7)
(30.3)
FLUID FLOW – gpm (lpm)
A
B
C
12
14
(53.0)
(45.4)
(60.6)
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

241906

Table of Contents