Fronius TransTig 1600 Operating Instructions And Spare Parts List page 41

Hide thumbs Also See for TransTig 1600:
Table of Contents

Advertisement

TR 50mc remote
With the TR 50mc remote control pulsing unit two operational modes are possible:
control pulsing
-
unit
-
(contiued)
(23) Pulsing current dial I
(24) Pulse frequency dial f (Hz)
(25) Background current dial I
(26) Duty-Cycle dial %
Setting-examples
Duty Cycle dial (26) is in scale position 50, (see Fig.23)
Fig. 23
Regulation of impulse current I
Adjustment of impulse current I
unit.
1
-
For continuous adjustment of the pulsing / main current
-
For continuous adjustment of the pulse frequency, depen-ding on which
frequency range has been preselected by switch (27).
-
The setting for the background current is made as a percentage of the value
set for the pulsing current I
-
Setting dial for pulse / interval relationship = this dial is for setting the relati-
onship, in percentage terms, between the pulsing current phase and the
background current phase.
Duty cycle dial (26) is in scale position 10,
-
Short pulsing current phase of 10 %
-
Long background current phase of 90 %
-
Low degree of heat impact.
-
Pulsing current phase and background current phase are equally long (each 50
%)
l
Means medium degree of heat impact.
Duty cycle dial (26) is in scale position 90,
-
Long pulsing current phase of 90 %
-
Short background current phase of 10 %
-
High degree of heat impact.
I
0
Setting-example Duty-Cycle in scale position "50"
by TR 50mc remote control unit.
1
by means of the TR 52mc remote control pedal
1
(main current)
2
1
T= 1/f
(Hz)
I
1
50%
Duty-Cycle
23
I
2
50%
t