Dual Display (VEL + Temperature, FLOW + AREA) Memory of 2000 Records One Shot or Continuous Recording Sampling time set by keypad RS-232C interface (PCE-007) ° C/ ° F Ergonomic and easy-to-use design Read while measuring (detached vane) Large 17mm 3 ½ digits LCD (Liquid Crystal Display)
2.1. LCD AVE: When method of average is selected by OPTION button for flow measurement, this symbol will appears. MIN: When MAX/MIN button is pressed twice, this symbol will appear to indicate MIN value of ever measured value for either velocity or flow is displayed in LCD 2/3V: This symbol will be displayed together with MAX when 2/3VMax method is selected by OPTION button in flow measurement.
3. Operation Instruction Figure 2 3.1. Measurement of Wind Velocity (refer to figure 2) 1. Press the on/off button to turn on the anemometer. 2. Select anemometer function by pressing the VEL/FLOW button (number 4). VEL symbol will appear in LCD. 3.
(number 0) button. The lower four digits will become blank, and anemometer wait for users to enter. 5. Press the OPTION button several times until none of AVE or 2/3VMAX is shown in LCD. 6. Users enter free area by pressing the numerical keypad. After free area is entered, press ENTER button to end.
3.8. To Record One Data (One Shot, Sampling Time = 0) 1. Set the sampling time to 0 by pressing the SAMPLE button (number 0) in the VEL mode (measuring velocity of wind). The previous stored sampling time will be displayed in upper LCD. 2.
4. WindowsTM Application Program 4.1. Installation of the WindowsTM Application Program 4.1.1. For Windows 3.1 A. Start MicrosoftTM WindowsTM B. Insert disk in drive A (or B) C. From Program Manager, select File menu and choose Run D. Type a:\setup (or b:\setup) and press Enter key 4.1.2.
Page 10
End Recording: End recording when selected. VIEW FILE: If the View option under FILE in the Main Window is selected, a view window will be shown as above, and the users can review your ASCII data file. If a printer is connected to the PC, users can print out content selectively.
Page 11
Standard deviation, best fit over the curve. This function is valid only when they are less than 3600 data. If there are more than 3600 data, STATIS will be disabled. Clear: Clear the graphic screen. Print: Print out the curve if a printer is connected to PC. DISPLAY: DISPLAY menu has four options: DIGITAL, ANALOG, LIST, and GRAPHIC.
Page 12
If this option is selected or CTRL+A is pressed, a window, which emulates an analog meter, shall appear on the screen. LIST: If this option is selected or CTRL+L is pressed, a window, which lists the date, function, range, and value every sampling, shall appear on the screen.
Datalogger: CALIBRATION DATA: They are the calibration data stored in memory of anemometer. They are used when returned for repair. DATALOGGER SETUP: They are the sampling time and total record numbers stored in anemometer. Time: This time will be used as initial time when converting data. This is a value entered by users. Down Load: When this button is pressed, program will ask the users to enter file name.
Page 14
ft/min knots Km/hr 1 m/s 196.87 1.944 3.60 2.24 1 ft/min 0.00508 0.00987 0.01829 0.01138 1 knot 0.5144 101.27 1.8519 1.1523 1 Km/hr 0.2778 54.69 0.54 0.6222 1 mph 0.4464 87.89 0.8679 1.6071 Range of Temperature: Range Resolution Accuracy ° C 0 - 45.0 ±1.0 °...
6. Battery Replacement When the low battery symbol is displayed on LCD, follow the following procedures to replace the battery. 1. Turn off the anemometer by pushing the On/Off button. 2. Remove the screw of the battery compartment cover and remove the battery compartment cover. 3.