HVAC Meter
PCE-007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCE-007 and is the answer not in the manual?

Questions and answers

Summary of Contents for PCE Instruments PCE-007

  • Page 1 PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13 Suite 8 Southpoint Business Park Jupiter Ensign way FL-33458 Hampshire / Southampton United Kingdom, SO31 4RF From outside US: +1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0...
  • Page 2: Table Of Contents

    Features .......................... 3 Front Panel Description ....................3 2.1. LCD ..........................4 Operation Instruction ..................... 5 3.1. Measurement of Wind Velocity (refer to figure 2) ............5 3.2. Measurement of Wind/Air Temperature ................ 5 3.3. Measurement of Wind/Air Flow (Instant Air Flow) ............5 3.4.
  • Page 3: Features

    Dual Display (VEL + Temperature, FLOW + AREA) Memory of 2000 Records One Shot or Continuous Recording Sampling time set by keypad RS-232C interface (PCE-007) ° C/ ° F Ergonomic and easy-to-use design Read while measuring (detached vane) Large 17mm 3 ½ digits LCD (Liquid Crystal Display)
  • Page 4: Lcd

    2.1. LCD AVE: When method of average is selected by OPTION button for flow measurement, this symbol will appears. MIN: When MAX/MIN button is pressed twice, this symbol will appear to indicate MIN value of ever measured value for either velocity or flow is displayed in LCD 2/3V: This symbol will be displayed together with MAX when 2/3VMax method is selected by OPTION button in flow measurement.
  • Page 5: Operation Instruction

    3. Operation Instruction Figure 2 3.1. Measurement of Wind Velocity (refer to figure 2) 1. Press the on/off button to turn on the anemometer. 2. Select anemometer function by pressing the VEL/FLOW button (number 4). VEL symbol will appear in LCD. 3.
  • Page 6: Measurement Of Wind/Air Flow (2/3Vmax Air Flow)

    (number 0) button. The lower four digits will become blank, and anemometer wait for users to enter. 5. Press the OPTION button several times until none of AVE or 2/3VMAX is shown in LCD. 6. Users enter free area by pressing the numerical keypad. After free area is entered, press ENTER button to end.
  • Page 7: To Record One Data (One Shot, Sampling Time = 0)

    3.8. To Record One Data (One Shot, Sampling Time = 0) 1. Set the sampling time to 0 by pressing the SAMPLE button (number 0) in the VEL mode (measuring velocity of wind). The previous stored sampling time will be displayed in upper LCD. 2.
  • Page 8: Down Load Data To Personal Computer (Avm-07)

    Byte8: Digit 3 (most significant) in upper LCD. Byte9: Digit 2 in upper LCD. Byte10: Digit 1 in upper LCD. Byte11: Digit 0 (least significant) in upper LCD. Byte12: Digit 3 (most significant) in lower LCD. Byte13: Digit 2 in lower LCD. Byte14: Digit 1 in lower LCD.
  • Page 9: Windowstm Application Program

    4. WindowsTM Application Program 4.1. Installation of the WindowsTM Application Program 4.1.1. For Windows 3.1 A. Start MicrosoftTM WindowsTM B. Insert disk in drive A (or B) C. From Program Manager, select File menu and choose Run D. Type a:\setup (or b:\setup) and press Enter key 4.1.2.
  • Page 10 End Recording: End recording when selected. VIEW FILE: If the View option under FILE in the Main Window is selected, a view window will be shown as above, and the users can review your ASCII data file. If a printer is connected to the PC, users can print out content selectively.
  • Page 11 Standard deviation, best fit over the curve. This function is valid only when they are less than 3600 data. If there are more than 3600 data, STATIS will be disabled. Clear: Clear the graphic screen. Print: Print out the curve if a printer is connected to PC. DISPLAY: DISPLAY menu has four options: DIGITAL, ANALOG, LIST, and GRAPHIC.
  • Page 12 If this option is selected or CTRL+A is pressed, a window, which emulates an analog meter, shall appear on the screen. LIST: If this option is selected or CTRL+L is pressed, a window, which lists the date, function, range, and value every sampling, shall appear on the screen.
  • Page 13: Specifications( 23 ± 5° C)

    Datalogger: CALIBRATION DATA: They are the calibration data stored in memory of anemometer. They are used when returned for repair. DATALOGGER SETUP: They are the sampling time and total record numbers stored in anemometer. Time: This time will be used as initial time when converting data. This is a value entered by users. Down Load: When this button is pressed, program will ask the users to enter file name.
  • Page 14 ft/min knots Km/hr 1 m/s 196.87 1.944 3.60 2.24 1 ft/min 0.00508 0.00987 0.01829 0.01138 1 knot 0.5144 101.27 1.8519 1.1523 1 Km/hr 0.2778 54.69 0.54 0.6222 1 mph 0.4464 87.89 0.8679 1.6071 Range of Temperature: Range Resolution Accuracy ° C 0 - 45.0 ±1.0 °...
  • Page 15: Battery Replacement

    6. Battery Replacement When the low battery symbol is displayed on LCD, follow the following procedures to replace the battery. 1. Turn off the anemometer by pushing the On/Off button. 2. Remove the screw of the battery compartment cover and remove the battery compartment cover. 3.