Date And Time; About; Remove Bonding Information; Presence Detection - Daikin BRC1H519K7 Installer And User Reference Manual

Wired remote controller
Hide thumbs Also See for BRC1H519K7:
Table of Contents

Advertisement

14 About the app
14.5.7

Date and time

Set the remote controller date and time. In the date and time menu
you send date and time information to the remote controller from the
app. You can choose to either send the date and time information of
your mobile device ("Synchronise with device date and time"), or to
manually create and send date and time information.
INFORMATION
If the controller is disconnected from the power for more
than 48 hours, the date and the time need to be set again.
INFORMATION
The clock will maintain accuracy to within 30 seconds/
month.
14.5.8

About

Read out the current remote controller and remote controller
Bluetooth module software version.
14.5.9

Remove bonding information

Make the controller forget all previously bonded mobile devices.

14.5.10 Presence detection

Set a timer for the system to adjust the temperature setpoint or to
turn off automatically, based on (the lack of) presence detected by a
motion sensor.
Action
Auto OFF
Setpoint adjustment
INFORMATION
To use this function, it is required that the indoor units are
equipped with a motion sensor (optional accessory).
INFORMATION
This function cannot be used when the indoor units are
controlled by a centralised controller.
INFORMATION
This function is not supported when the system contains
Sky Air RR or RQ outdoor units.
INFORMATION
This function cannot be used when the indoor units are in
group control.
INFORMATION
For systems in which the indoor units run in simultaneous
operation, this function is controlled by the motion sensor
mounted in the master indoor unit.
Installer and user reference guide
38
Description
Set an OFF timer that starts
running as soon as the motion
sensor detects the room is
unoccupied.
Set setpoint adjustment
increments and intervals for both
heating and cooling operation.
When the motion sensor detects
the room is unoccupied, the
system will raise (cooling
operation) or lower (heating
operation) the setpoint, until the
set limit is reached.

14.5.11 OFF timer

Set a timer for the system to turn OFF automatically. The timer can
be enabled or disabled. When the timer is enabled, it starts running
each time the system gets turned ON.
The timer has a range of 30~180 minutes, and can be set in
increments of 10 minutes.

14.5.12 Energy consumption

See and compare energy consumption data.
INFORMATION
The availability of this function depends on the type of
indoor unit.
INFORMATION
This function cannot be used when the indoor units are in
group control.
INFORMATION
This function is not supported when the system contains
Sky Air RR or RQ outdoor units.
INFORMATION
The displayed energy consumption can be different
from the actual energy consumption. The displayed
data is not the result of a kWh measurement, but the result
of a calculation based on measured operation data. Some
of that operation data are absolute values, but some are
interpolations, including room for interpolation tolerance.

14.5.13 Power consumption limit

Set a timespan in which the system limits its peak power
consumption. When enabled, this function makes the outdoor unit
operate with limited energy consumption (70% or 40% of usual
consumption) in the set timespan.
INFORMATION
The availability of this function depends on the type of
outdoor unit.

14.5.14 Setpoint auto reset

Set a timer for the system to automatically adjust the temperature to
a set temperature value. The timer can be enabled or disabled for
Heating and Cooling operation separately. When a timer is enabled,
it starts running each time the system gets turned ON. When the
timer runs out, the temperature setpoint will always change to the set
value, also if the temperature setpoint has been changed in the
meanwhile.
The timer has a range of 30~120 minutes, and can be set in
increments of 30 minutes.
INFORMATION
This function cannot be used when the indoor units are
controlled by a centralised controller.

14.5.15 Schedule

Organise system actions into schedules. The schedule function
allows you to set up to 5 timed actions for each day of the week. It is
possible to create up to 3 different schedules, though only 1
schedule can be active at the same time.
The action logic is as follows:
1
Set a timespan for the action.
2
Choose to turn system operation ON or OFF, and set the
conditions.
BRC1H519W+K+S7
Wired remote controller
4P513689-1D – 2019.05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brc1h519s7Brc1h519w7

Table of Contents