Trap - TRENDnet PoE Web Smart Switch Series User Manual

Hide thumbs Also See for PoE Web Smart Switch Series:
Table of Contents

Advertisement

TRENDnet User's Guide

Trap

System > SNMP > Trap
A Host IP address is used to specify a management device that needs to receive SNMP
traps sent by the switch. This IP address is associated with the SNMP Version and a valid
Community Name in the Host table of the switch.
1. Log into your switch management page (see
on page 5).
2. Click on System, click on SNMP, and click on Trap.
3. Review the settings.
Create Trap Host Table Entry
Use the following procedure to create a trap Host table entry:
Enable trap management by selecting the radio button next to Enabled at the
top of the page. By default, trap management is enabled.
Enter the Host IP Address for the management device that is to receive the
SNMP traps.
Enter the SNMP Version, either v1 or v2c, that is configured for the host
management device.
Enter a Community Name that you have defined previously in the SNMP
Community table. The Community Name must correlate with one of the
communities displayed on the SNMP Community Table page. If you enter a
Community Name that has not been pre-defined, the Trap Host entry is
displayed, but agent/manager communication fails.
Click Add. The new host is added to the table.
© Copyright 2018 TRENDnet. All Rights Reserved.
"Access your switch management
page"
Modify a Trap Host Table Entry
If you need to modify an SNMP Trap entry, you must first delete the entry by using the
procedure below and then re-enter it with the modification by creating a new SNMP
trap.
Delete a Trap Host Table Entry
To delete an entry in the host table, click Delete next to the entry in the table that you
want to remove. The Host table entry is removed from the table. No confirmation
message is displayed.
4. At the bottom of the left hand panel, click Save.
5. Select the Config you would like to save the settings to, click Save Settings to Flash,
then click OK.
Note: This step saves all configuration changes to the NV-RAM to ensure that if the
switch is rebooted or power cycled, the configuration changes will still be applied.
PoE Web Smart Switch Series