SPECIFICATIONS
MOTOR: (24KT AND STANDARD COMPRESSORS)
Type
Size
Speed
Starter
Shaft Diameter
Type
Size
Speed
Starter
Shaft Diameter
FOR 50 HZ COMPRESSORS
Type
Size
Speed
Starter
Shaft Diameter
Type
Size
Speed
Starter
Shaft Diameter
Type
Size
Speed
Starter
Shaft Diameter
LUBRICATION
PRESSORS
Sullair standard compressors are filled with SRF
1/4000 fluid as factory fill.
Mixing of other fluids within the compressor will
void all warranties.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
14
30HP
60Hz, 3 Phase, ODP , 460V, A.C. 40_C Maximum Ambient Temperature
Options: 200V to 230V and 575V
TEFC Also Available
1800RPM
460V Magnetic Full Voltage
Options: 200V to 230V and 575V
1%@ 8 " (41.3mm)
40HP
60Hz, 3 Phase, ODP , 460V, A.C. 40_C Maximum Ambient Temperature
Options: 200V to 230V and 575V
TEFC Also Available
1770RPM
460V Magnetic Full Voltage
Options: 200V to 230V and 575V
1&@ 8 " (47.6mm)
25HP
60Hz, 3 Phase, ODP , 380V, A.C. 40_C Maximum Ambient Temperature
1500RPM
380V Magnetic Full Voltage
Options: 415V
1%@ 8 " (41.3mm)
30HP
60Hz, 3 Phase, ODP , 380V, A.C. 40_C Maximum Ambient Temperature
1500RPM
380V Magnetic Full Voltage
Options: 415V
1%@ 8 " (41.3mm)
40HP
50Hz, 3 Phase, ODP , 380V, A.C. 40_C Maximum Ambient Temperature
Options: 415V
TEFC Also Available
3000RPM
380V Magnetic Full Voltage
1%@ 8 " (41.3mm)
GUIDE-- STANDARD
WARNING
!
COM-
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
LUBRICATION GUIDE-- 24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which normally does not need to be changed. In
the event a change of fluid is required, use only Sul-
lair 24KT fluid.
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullair recommends that a 24KT sample be taken
at the first filter change and sent to the factory for
WARNING
!