What's in the Box?
LP-51xx module microSD card Software Utility CD Screwdriver RS-232 Cable
Preparing to start your LP-51xx
Power Supply: +10V to +30V
http://www.icpdas.com/products/Accessories/power_supply/power_list.htm
Diagram of the LP-51xx
1
USB Port
Ethernet Port
2
Ethernet Port
3
4
Microphone In
5
Earphone Out
ICP DAS
A
C
-
5
1
A
C
-
5
1
DC
6
COM 1 (RS-232)(console)
COM 2 (RS-485)
7
COM 3 (RS-232)
8
9
DC (PWR, GND)
10 Frame Ground
LinPAC-51xx Quick Start
x
x
Q
u
x
x
Q
u
(E.g., DP-665)
i
c
k
S
t
a
i
c
k
S
t
a
Version 1.4 2013/06/06
11 LED Indicator
12 microSD socket
13 VGA Port
14 XWboard (optional)
15 Operating Modes Selector
r
t
r
t
- 1 -

Advertisement

loading

Summary of Contents for ICP DAS USA LinPAC-51 Series

  • Page 1 Version 1.4 2013/06/06 What’s in the Box? LP-51xx module microSD card Software Utility CD Screwdriver RS-232 Cable Preparing to start your LP-51xx Power Supply: +10V to +30V (E.g., DP-665) http://www.icpdas.com/products/Accessories/power_supply/power_list.htm Diagram of the LP-51xx USB Port COM 1 (RS-232)(console) 11 LED Indicator Ethernet Port COM 2 (RS-485) 12 microSD socket...
  • Page 2: Configuring The Operating Mode

    Configuring the Operating Mode Enure the rotary switch is in the “0” position Rotary Switch Position Operation Mode Normal Mode(Default) Quick Mode OS Update Mode Debug Mode Others Reserved Normal Mode(Default) Normal mode is the default operation mode for the LP-51xx. Use this mode to perform additional tasks and configuration.
  • Page 3 Connecting the LP-51xx to a Windows PC The RS-232 connector is a standard non-isolated serial port (COM1 - TxD, RxD, GND), and is located on the upper right-hand corner on the LP-51xx module. Connect the LP-51xx console to the COM port on the Host PC. Note that it is unnecessary to connect to a converter.
  • Page 4 Turn on the LP-51xx power and the following message will be displayed to indicate that the configuration process has been completed. Press ‘Enter’, you will see ‘linpac-51xx login:’ prompt. At the LP-51xx login prompt, enter the root ID and password (Default ID and password is root).
  • Page 5 Connecting the LP-51xx to a Linux PC Install a HyperTerminal tool on the Linux PC, such as Minicom, or GTKTerm, etc. Using Minicom as an example: In the terminal window, type ’minicom -s’ to enter the Minicom configuration menu. To configure the COM1 port, use the keyboard arrow keys to select the menu item labeled ‘Serial port setup’...
  • Page 6 A sample of the Minicon operation. Turn on the LP-51xx power. Once the boot sequence is complete, press ‘Enter’, you will see ‘linpac-51xx login:’ prompt. At the LP-51xx login prompt, enter the root ID and password (Default ID and password is root). ICP DAS LinPAC-51xx Quick Start - 6 -...
  • Page 7 to the LP-51xx via Telnet Connect In HyperTerminal: On a Linux PC On a Windows PC ICP DAS LinPAC-51xx Quick Start - 7 -...
  • Page 8: Technical Support

    Configuring the IP Address for the LP-51xx There are two methods of assigning the LP-51xx network settings. The first uses DHCP and the other uses a manually Assigned IP address. The factory default setting for the LP-51xx is DHCP, and this is the easiest method. However, if your network system does not include a DHCP server, then you will need to manually configure the network settings by using the Assigned IP method.

This manual is also suitable for:

Linpac-5131Linpac-5141Linpac-5141-odLinpac-5131-odLinpac-5331Linpac-5431 ... Show all