Connection

6.8 Installing the strain relief

6.8
Installing the strain relief
Strain relief for the device is provided in the scope of delivery. The strain relief is designed to
prevent the lines connected to the device from being accidentally pulled out.
Attaching PROFINET strain relief
Requirement
● 1 strain relief
● 2 screws
● 1 T10 screwdriver
Mounting
1. Remove the marked countersunk
screws.
2. Fasten the strain relief at the PROFI‐
NET interface(s).
Use the oval head screws included
with the strain relief.
Removing
Follow the mounting procedure in reverse to remove the strain relief.
Securing cables generally
Secure all cables connected to the device at the cable grip, each with a cable tie. The required
cable ties are not part of the scope of delivery.
Requirement
● Maximum of 6 cable ties for USB, Ethernet, PROFIBUS
Maximum cable tie width 3 mm.
● 1 cutting tool
Procedure
1. Place the cable tie around the attachment plate of the strain-relief assembly and secure
the plugged-in cables.
2. Cut off the cable tie overhang.