Test Operation - Fisher & Paykel CG604DX1 Installation Instructions Manual

Table of Contents

Advertisement

14
AFFIX DUPLICATE DATA LABEL SOMEWHERE
ACCESSIBLE & PLUG COOKTOP IN
Duplicate data
label

TEST OPERATION

16
To check that the ignition system operates correctly, light each burner by itself, then all burners in
combination.
Check for a well‐defined blue flame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact Customer Care or your nearest F&P Authorised
Service Centre.
The cooktop must not be used by the customer until proper operation has been achieved.
lifting o
x 4
yellow tip
good ame
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
15
FIT PAN SUPPORTS
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
If connecting the gas with a exible hose:
Ensure the pan supports are located securely
and in the correct orientation (refer to User guide)
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certi ed, with an Rp ½" (ISO 7 1) female th
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
GAS
GAS
ON
ON
10
check all connect