ONTENT UBJECT NTRODUCTION 1.1. LEVEL-2D ESCRIPTION OF THE REPARATION AND TART 1.2.1 ATTERIES 1.2.2 OSSIBLE ONFIGURATIONS TARTING PERATION HORT DESCRIPTION 2.1.1 VERVIEW KEYBOARD AND DISPLAY 2.1.2 OW TO SWITCH THE INSTRUMENT 2.1.3 UNCTIONS HORT DESCRIPTIONS OF EACH SINGLE KEY ISPLAY 2.2.1 CALING OF THE ISPLAY...
Page 4
.w ylerag.com/en/support/certificates/ • Imagefilms, Instructional videos and Tutorials https://w w w .youtube.com/user/w ylerag • Manuals und Compendium http://w w w .w ylerag.com/en/support/documentation/manuals/ • Representatives WYLER AG/ Product Training http://w w w .w ylerag.com/en/contact/representatives/ page 4 of 65 pages...
Page 5
INDEX Key w ord Chapter Page BSOLUTE MEASUREMENT ELATIVE MEASUREMENT / FILTER DJUSTMENT OF ILTER TYPES / DISPLAY DJUSTMENT OF THE DISPLAY / UNIT DJUSTMENT OF THE MEASURING UNIT APPENDICES 2.2.3 ACKGROUND COLOUR 1.2.1 ATTERIES 2.2.4 RIGHTNESS ONFORMITY ECLARATIONS AND PPROVALS LEVEL-2D ESCRIPTION OF THE...
Page 6
ZERO REL ZERO EASURING ELATIVE / LIMITS EASURING WITH LIMITS ENU SELECTION LEVEL-2D PERATING INSTRUCTIONS PERATION HORT DESCRIPTION PTIONS 2.1.1 VERVIEW KEYBOARD AND DISPLAY QUERY FOR ACCESS TO THE PTIONS 1.2.2 OSSIBLE ONFIGURATIONS REPARATION AND TART ROGRAMMABLE "REL ZERO" "ZERO/SELECT" / P ROGRAMMABLE ROGRAMMABLE ON/OFF...
Filter settings It is possible to send the measured data via an RS232 port to a PC/laptop and therewith to the WYLER software LEVELSOFT PRO, MT -SOFT and LabEXCEL software. The BlueLEVEL-2D contains two sensors based on the analog measuring principle . The analog measuring principle is optimized for the measurement of straightness, flatness, etc.
1.2.2 P OSSIBLE ONFIGURATIONS Stand-alone instrument BlueLEVEL-2D connected via an USB cable to a PC/Laptop A BlueLEVEL-2D connected to a laptop with the RS232 cable. The instrument is powered from an external power supply page 8 of 65 pages...
Page 9
Two BlueLEVEL-2D connected via Bluetooth to a BlueTC and to a laptop. Two BlueLEVEL-2D connected via Bluetooth to a BlueMETER SIGMA and to a laptop. Please check the respective manuals and data sheets for detai ls on the other products shown above.
TARTING PERATION HORT DESCRIPTION 2.1.1 O VERVIEW KEYBOARD AND DISPLAY Colour-display <ZOOM OUT> <ZOOM IN> <previous option> <next option> <ON/OFF> <select menu> <accept selection> <save entry> <to print measuring value> <unfreeze and print / transmit HOLD - inclination value> <escape from the menu> To use current inclination as <Freeze>...
2.1.2 H OW TO SWITCH THE INSTRUMENT The BlueLEVEL-2D features an automatic shut off. In normal mode the instrument is automatically switched off 60 minutes after the last key operation. This automatic shut OFF function can be deactivated with a special ON sequence or when using an external power supply...
Page 12
[sss xxxxxtt sn.nnnnnn xxxxxtt sn.nnnnnn <cr>] 0 .. 255 – sequence number sss = xxxxxtt = Sensor Serial Number and Type e.g. N2473Dx BlueLEVEL-2D X-Axis N2473Dy BlueLEVEL-2D Y-Axis sn.nnnnnn = inclination in rad, e.g. +0.226349 +9.999999 -> Positive Overrange -9.999999 -> Negative Overrange Example: 112 N2473Dx -0.021033 N2473Dy +0.002289...
Zero. ISPLAY The BlueLEVEL-2D features various graphic displays which can be scaled according to the requirements of the measuring task. Also the background colour and the brightness of the display can be adjusted.
Switch the logarithmic scaling ON or OFF using the keys . The display will show the requested state of the instrument. Confirm with the key The instrument will return to the measuring mode. If the logarithmic scaling is enabled, the symbol "LOG" will appear below the graph. 2.2.2 D ISPLAY TYPES The display type can be selected in the menu "display".
The following display types are available in the BlueLEVEL -2D: Numeric display Display with cross vial Display target Display LED-cross 2.2.3 B ACKGROUND COLOUR In the adjustments of the instrument the background colour can be selected. Depending on the brightness of the colour selected the colour of the fonts and the symbols will change between black and white.
2.2.4 B RIGHTNESS Adjustment of the brightness of the display. Difference between battery operation and the use of an external power supply. In the adjustments of the instrument the b rightness of the display can be adjusted in order to adapt it to the environmental conditions and to optimise the battery life time.
HORT DESCRIPTION OF THE INDIVIDUAL DISPLAY AREAS Main In the main display the actual measurin g value will be displayed. display Display of the A symbol indicates the direction of the inclination of the value direction of the displayed. inclination inclined to the right (positive inclination) declined to the right...
LEVEL-2D PERATING INSTRUCTIONS The BlueLEVEL-2D offers a wide range of functions and adjustment possibilities. The list of functions appears when the key is pressed. With the keys the desired function can be selected and with it will be started. If during 10 seconds n o further key is operated, the function list will be left.
Page 19
Notice: The value of the "ZERO OFFSET" determined by a reversal measurement corresponds to the deviation of the zero point of the BlueLEVEL-2D compared to the absolute Zero (gravity). The displayed measuring value corresponds to VALUE displayed = Value of the BlueLEVEL-2D minus "ZERO OFFSET"...
UNIT ELECTION OF THE MEASURING UNIT 3.2.1 S TANDARD UNITS You can change the measuring unit of the inclination values displayed. If yo u start the function [UNIT] the list of the available measuring units will appear. With the keys you can now select the measuring unit preferred.
UNCTION The key function can be applied in all measuring modes. Put the BlueLEVEL-2D on a stable support. Press now the key . While the BlueLEVEL-2D is waiting for a valid measuring value the display will show graphically the measuring values read in the form of a shoal of points. As it is...
3.5.1 BSOLUTE MEASUREMENT As a factory setting the BlueLEVEL-2D will be programmed for absolute measurement (default setting). If this is not the case select the function [Absolute]. After confirming this function with the key the instrument is ready for measurements in the mode "ABSOLUTE".
Inclination X: 0.996mm/m Inclination Y: 2.311mm/m Set the BlueLEVEL-2D to the correct position and press the key After 15 seconds the value will automatically be read. During the measurement the display will graphically show the current measurement.
The v alue displayed is "0" and represents the position of the reference defined. LIMITS EASURING WITH LIMITS If you intend to set off an "Alarm" when a defined limit is exceeded this can be realised using the function "LIMITS". The function "LIMITS"...
Page 25
= 0 .. 255 - Laufnummer xxxxxtt = Sensor Serial Number and Type N2673Dx BlueLEVEL-2D X-Axis N2673Dy BlueLEVEL-2D Y-Axis sn.nnnnnn = +9.999999 - Positive Overrange -9.999999 - Negative Overrange other value - angular value in rad e.g. +0.226349 sm.mmmmmm =...
"JOIN" procedure for cables will be performed. To make sure that the instrument does not belong to another group, it is advisable to perform the function "LEAVE" first. 1. On the BlueLEVEL-2D select the menu "JOIN" using the key. Confirm with Set the second instrument also to the JOIN mode.
1. On the BlueLEVEL-2D select the menu "LEVAE" using the key. Confirm with 2. The BlueLEVEL-2D is now unhinged from the group and is no longer accessible via wireless data transmission. TEACH-IN of the IR-trigger (Zapper) In order to eliminate interference of the zapper signals when several measuring groups are active in...
PTIONS The options serve for entering the basic adjustments of the measuring instrument. The access to the options can be protected with a PIN code in order to avoid unauthorised modifications. The following options are available: Option "Set PIN-Code" With this option it is possible to block the entering of options with a PIN code.
PIN-C In order to protect the settings of the BlueLEVEL -2D against unauthorised changes you have the possibility to block the entering of options with a PIN code. Using the key select the menu point [Options] and confirm with . Select now [Set Pin Code] and confirm with Switch the blocking of options with the keys ON and confirm with the key...
Using the key select the menu point [Options] and confirm with . Select now [Display Settings] and confirm with With the keys select the display option you would like to change and confirm the selection with the key In the brightness adjustments you can increase or reduce the brightness using the keys .
ROGRAMMABLE The function of the keys as well as the key can be switched on or off. Using the key select the menu point [Options] and confirm with . Select now [Programmable keys] and confirm with Select the key you want to activate or deactivate using the keys and confirm your choice with the key With the keys you can switch the selected key...
ON/OFF UNCTIONS The menu functions provided can be switched on respectively off. Thus the menu displayed can be adjusted to the needs of the user. Using the key select the menu point [Options] and confirm your selection with . Select now [Functions ON/OFF] and confirm with Select the function you want to switch on respectively off with the keys...
Manila 9.784 T okyo 9.798 The BlueLEVEL-2D has been calibrated Copenhagen 9.815 Mexico City 9.779 Vancouver, BC 9.809 at the head office of WYLER AG. The Nicosia 9.797 New York 9.802 Washington, DC 9.801 Jakarta 9.781 Oslo 9.819 Wellington, NZ 9.803...
Switch the correction of the gravitation ON or OFF using the keys and confirm with the key Now you can enter the value of the local gravity. The value is adjusted with the keys . With the key the standard value 9.80700 m/s will be recalled.
ACTORY ESET A complete factory reset will reset the instrument to the state as it has been configured at the factory. All personal settings are lost. The BlueLEVEL-2D will be set to the following standard configuration: Standard-Values: measuring mode: absolute measuring unit: DEC xx°xx'xx"...
4.12 UNCTION HECK At the start of the instrument a system test will be performed, checking the most important functions. In addition to this test the functions of the keys and of the LEDs can be checked. Using the key select the menu point [Options] and confirm your selection with .
Page 62
ERROR 6 Defective EEPROM AINTENANCE ENERAL The BlueLEVEL-2D needs no special service other than the regular cleaning. / CARE TORAGE AND HANDLING OF THE BATTERIES For storage periods the measuring instrument should be placed in a position i n which the instrument is also used when measuring (upright position).
Page 63
The invoicing will be through the WYLER partner in your country. Please do not hesitate to make use of this service in order to have your WYLER instrument back at your disposal as soon as possible. In case of any questions please contact WYLER SWITZERLAND or your local distributor, we will gladly help you to use the ERS successfully.
Page 64
ONTRACTS Measuring systems are becoming more and more complex and are therefore subject to continuous supervision in respect of quality and reliability. For this purpose WYLER AG offers the option of a MAINTENANCE CONTRACT with the purchase of new i nstruments.
Page 65
WYLER AG Tel. 0041 (0) 52 233 66 66 Im Hölderli Fax. 0041 (0) 52 233 20 53 CH-8405 WINTERTHUR Switzerland Homepage: http://w w w .w ylerag.com E-Mail: w yler@w ylerag.com...
Need help?
Do you have a question about the BlueLEVEL-2D and is the answer not in the manual?
Questions and answers