Preface; Purpose, Boiler Operational Conditions - SAS BIO SOLID 19 Operation And Maintenance Manual

Table of Contents

Advertisement

Dear Buyer and User of the low-temperature SAS BIO SOLID boiler. This ope-
rating and maintenance manual contains all necessary information for energy-effi-
cient, safe and long operation of your boiler. The device is delivered together with
a set of operating and maintenance manuals for operation of the boiler, burner and
controller.
Before installation and operation of this device you must read and understand
contents of this operating and maintenance manual. After acquainting with this ma-
nual you will be able to use this device in an optimum way. By becoming thoroughly
acquainted with this manual you will be able to operate the boiler in an effective and
safe way.
Boilers manufactured by the Zakład Metalowo-Kotlarski "SAS" meet the requ-
irements of relevant EU directives and are CE-marked, and this is confirmed in the
enclosed EC DECLARATION OF CONFORMITY.
THIS DOCUMENTATION SHOULD BE KEPT FOR FUTURE USE, IT IS ALSO
A WARRANTY CARD FOR THE BOILER.

2. PURPOSE, BOILER OPERATIONAL CONDITIONS

SAS BIO SOLID boilers with a fuel tank and SAS MULTI FLAME burner are
designed for installation in water central heating systems, open/close system*
with gravitational or forced water flow, secured according to current local or EU
regulations (PN-EN 12828+A1:2014-05 Heating installations in buildings. De-
sign of water-based heating systems). They are recommended, in particular, for
heating of residential flats in one- and multi-family houses, and for commercial,
services, catering and workshop facilities, etc., in which maximum acceptable
working temperature of supplied water does not exceed 85°C, and a maximum
working pressure in the system does not exceed 1.5 bar. Required minimum
flue gas pass downstream the boiler od 0,20-0,30 mbar, depending on the no-
minal thermal power (according to PN-EN 13384-1:20152008 Chimneys. Me-
thods for thermal and flow-through calculations. Part 1: Chimneys serving one
heating appliance).
* The installed system must meet specific requirements of standards in force in a country of destination con-
cerning safety devices for water-based heating equipment in open vented systems,and expansion vessels in
an open vented or sealed systems together with accessories: diaphragm expansion vessel, pressure relief
valve, equipment for control and measurements, or devices for removing excess heat.

1. PREFACE