It is recommended to leave doors (clean out, furnace, ash-box) and clean out
holes open during this operation, to prevent corrosion resulting from water con-
densation on cold walls of the heat exchanger.

9. CONDITIONS FOR SAFE OPERATION

To maintain safe operational conditions for the boiler, the following rules must
be observed:
the boiler can only be operated by adults, according to guidelines provi-
ded in the documentation supplied together with the device;
all connections to the power supply system can only be made by a per-
son holding relevant qualifications – Polish Electricians Association li-
cence up to 1kV;
children cannot remain unattended in the boiler vicinity, or have access
to the controller and to moving components of the boiler;
the boiler and the associated system must be kept in the correct ope-
rational condition, and in particular, system tightness and tightness of
doors and clean out hatches must be ensured;
maintain order in the boiler room and do not stack any objects not used
for boiler operation or flammable materials;
during winter avoid breaks in heating to prevent freezing of water in the
system or its part. Freezing, particularly of safety (overflow) pipes is very
dangerous, as it may result in the boiler damage;
it is forbidden to fire the boiler using flammable materials such as petrol,
kerosene, or solvents, as this may result in explosion or burning of the user;
before each firing and regularly during operation check the amount of
water in the heating system and ensure the valves between the boiler
and the system are opened;
during the boiler operation the heating water temperature cannot exceed
85°C;
in the event of the system failure, when there is no water in the boiler do
not replenish it when the boiler is very hot, because this may result in the
boiler failure;
all activities related to the boiler operation should be performed in pro-
tective gloves and with particular care observed; all boiler defects must
be remedied immediately.
NOTICE: The boiler must be regularly cleaned of soot and tar – any de-
posits on convection duct walls affect correct heat transfer
from the exchanger, reducing the device performance and in-
creasing fuel consumption.
The pellet feeder is designed in a way not requiring complicated operation
and expensive maintenance. However, its correct operation (influencing boiler
performance and burning economy) requires certain rules to be observed during
the feeder operation and regular performance of certain activities.