Turntable Bearing Lubrication - Stanley Labounty MDP Series Safety, Operation & Maintenance

Mobile demolition processor
Table of Contents

Advertisement

TURNTABLE BEARING LUBRICATION

Stand clear of MDP during rotation.
1. The turntable bearing has 1 to 4 grease fittings,
depending on model type. Use lithium Grade 2 extreme
pressure grease.
Note: For operation below 0° F, use grade 0 grease.
2. Grease a fitting with 4 shots (.2 oz) of grease.
3. Stand clear and rotate the attachment 360°.
4. Grease the same fitting with 4 more shots (.2 oz)
of grease, or until grease starts to escape from the
bearing seals.
5. Perform steps 1 through 3 for every grease fitting.
PLANETARY GEARBOX LUBRICATION (SELECT MODELS ONLY)
Some models use a planetary gearbox to rotate the attachment. The gearbox oil must be changed regularly,
based on the Planetary Gearbox Oil Change Schedule.
Planetary Gearbox Location
Figure 20
18 | MDP Operation & Maintenance Manual
Planetary Gearbox Oil Change Schedule
1000 hours / 2 years
500 hours / 1 years
Synthetic ISO 150 @
SAE 80W - 90
104° F
OiL FiLL PLug
OiL DrAiN PLug
Turntable Lubrication Access
Figure 19
Every 1000 hours / 2
years
Synthetic ISO 150 @
104° F
1. Access the gearbox.
2. Remove the oil fill plug.
3. Remove the oil drain plug. Drain oil into a
container larger than 2 quarts.
Note: The plugs are magnetic and will collect metal
filings. Discard the filings.
4. Install the oil drain plug.
5. Fill the gearbox with oil, as specified in the parts
manual.
6. Install oil fill plug.
TurNTABLe BeAriNg