Dismantling

Disconnecting/
turning off
10
Follow the steps below in order to disconnect the ACT-7.
Failure to follow the procedure may result in excess water being retained in the system which
may spill when the ACT-7 is moved.
Step Action
1
Switch to standby mode.
Keep the unit in this mode for at
least 30 minutes in order to let the
condensate pump drain the system.
2
When you have waited for
30 minutes, you can disconnect:
a.
mains power to room unit and
b. power cord between heat
exchanger and room unit.
3
Disconnect drain hose from the
heat exchanger:
a.
Use a screwdriver to remove
the blue collet from the hose
connector.
b. Push darker grey ring 'in' and
pull at the same time the hose
to remove.
Repeat step b to remove the hose
from the room unit.
4
Disconnect pipes from
a.
room unit and
b. heat exchanger
Pull the coupling of the female pipe
adapter back in order to disconnect
the pipes.
!
Be prepared with an old cloth or
alike to wipe the water/glycol mix-
ture up, since it will spill a bit, when
the pipes are disconnected.
Installation: Dismantling
Illustration
a
a
a
b
b
b