4.6.6
4–14
Programming the Scanner
Programming Flow
1.
Enter Prefix/Suffix programming.
2.
Select Prefix programming.
3.
Set the LRC value to the computed X'ored (Hex) value (87XX)
4.
Scan the required prefix as a Hex value.
5.
Select Suffix programming.
6.
Scan 86 to transmit the LRC to transmit as one character.
7.
Scan the required suffixes as Hex values.
8.
Exit Prefix/Suffix programming mode.
Programming Steps
1.
Scan the Enter label on the Prefix/Suffix menu page.
2.
On Bar Code Chart I, scan Roman Numeral I.
3.
On Bar Code Chart III, scan
4.
On Bar Code Chart III, scan 02
5.
On Bar Code Chart I, scan Roman Numeral II.
6.
On Bar Code Chart III, scan 86.
7.
On Bar Code Chart III, scan
8.
Scan the Exit label.
Data will be transmitted to the host as [STX]data[LRC][CR][ETX]

Code Selection I (Industrial) Menu Page

The SCANTEAM 3700PDF autodiscriminates between the following Industrial
symbologies: Codabar, Code 39, Interleaved 2 of 5, and Code 128.
The Code Selection I (Industrial) page of the SCANTEAM PDF417 Programming Menu
is used to disable or enable all Industrial symbologies. When a symbology is disabled,
the unit ignores any scans of that particular symbology. No error signal (beep) is issued.
Available Industrial symbologies and their options are listed in Table 4.6. Minimum and
Maximum lengths are selectable for all Industrial symbologies.