Scanteam 3700 Code Id Values - Welch Allyn SCANTEAM 3700 CCD Technical Manual

Table of Contents

Advertisement

Set Preamble Command Kd
COMMAND
Parameter ASCII
Enable
Data
Sending the configuration command Kd sets the preamble characters. The preamble
option may be enabled or disabled; if enabled, up to four preamble characters may be
defined. Any ASCII character can be specified except NUL, ACK, NAK, DC1, DC2,
DC3, DC4 or DEL. The character SUB should only be used as the first character in a
pair, with the second character being either a 1 or a 2. SUB 1 causes the 3700 to include
the Port ID in the preamble, while SUB 2 specifies that the Code ID should be included.
Table 4.1 lists the Code ID values. The default setting is preamble enabled, Port ID and
Code ID characters sent with data strings.
Tip:
When character pairs SUB 1 and SUB 2 are specified in the preamble, the SUB
characters are not counted toward the maximum number of ASCII characters
allowed (four).
Code ID Value
a
b
e
j
c
d
SPACE
Table 4.1 SCANTEAM 3700 Code ID Values
<Kd enable, data>
Option
0
no
1
yes * (Port ID, Code ID)
one to four ASCII characters
Definition
Codabar
Code 39
Interleaved 2 of 5
Code 128
UPC
EAN
No code
Configuring the SCANTEAM 3700
4–7