8 DISASSEMBLY-REASSEMBLY

Prior to any disassembly, shut off the motive
source. Disconnect the submersible automatic
sump drainer at the inlet and discharge
connections. Remove the unit from the sump.
a. Water or steam nozzle and delivery jet
disassembly
1. On 2R-x models remove plug (38A) and the
water or steam nozzle (61) from the ejector
body.
2. On 2R-xL models remove the loop (283) then
water or steam nozzle (61) from the ejector
body.
3. Remove the discharge elbow (206) and
delivery jet (82) from the ejector body.
Reassembly
4. Reverse the procedure for reassembly.
b. Float disassembly
1. The hanger (279) is removed from the float
(151) by unfastening the hanger screw
(100A) and lock washer (125B).
2. Remove the valve body (11) and tube washer
(125A) from the float guide tube (278).
3. Slide float off the guide tube.
4. Loosen guide tube from the ejector body
(11A).
5. Remove the hanger from the valve lever
(261).
Reassembly
6. Reverse the procedure for reassembly.
c. Valve disassembly
1. Remove the hanger (279) from the float (151)
by unfastening the hanger screw (100A) and
lock washer (125B).
2. Remove the valve body (11) from the float
guide tube (278). On 2R-L models it will be
necessary to take the loop (283) off prior to
removing the valve body.
3. Remove the valve body plug (38). On 2R-L
models remove the adapter (134) as well.
4. Loosen and remove the valve bonnet (20).
5. The valve disc holder (110) as well as the
valve disc (43) and screw (100) may be
removed at this time.
6. To disassemble the valve packing, remove
pin (17) from lever (261) and slide lever off
stem. Loosen valve packing gland (87) from
valve bonnet and remove. Valve packing
(211) and gland washer (125) may be pulled
out from valve bonnet.
7. Valve seat (16) may now be unscrewed from
valve body.
Reassembly
8. Reverse the procedure above.
9. Replace the two valve packings (211) and
valve disc (43) with new.
10. Do not over tighten the valve packing
gland (87). Doing so will affect valve lever
movement.

9 DISPOSAL AT END OF USEFUL LIFE

Penberthy submersible automatic sump
drainers are used in a variety of fluid
applications. By following the appropriate
federal and industry regulations, the user
must determine the extent of preparation
and treatment the submersible automatic
sump drainer must incur before its disposal.
A Material Safety Data Sheet (MSDS) may be
required before disposal services accept certain
components.
Metal, glass and polymers should be recycled
whenever possible. Refer to order and
applicable technical data sheets for materials of
construction.

10 TELEPHONE ASSISTANCE

If you are having difficulty with your
submersible automatic sump drainer, contact
your local Penberthy distributor. So that we
may assist you more effectively, please have as
much of the following information available as
possible when you call:
- Model #
- Name of the company from whom you
purchased the submersible automatic sump
drainer
- Invoice # and date
- Process conditions (pressure, flow rates, tank
shape, etc)
- A brief description of the problem
- Trouble shooting procedures that failed
If attempts to solve your problem fail, you may
request to return your submersible automatic
sump drainer to the factory for intensive
testing. You must obtain a Return Authorization
(R.A.) number from Emerson before returning
anything. Failure to do so will result in the unit
being returned to you without being tested,
freight collect. To obtain an R.A. number, the
following information (in addition to that above)
is needed:
- Reason for return
- Person to contact at your company
- 'Ship-to' address
There is a minimum charge for evaluation
of non-warranty units. You will be contacted
before any repairs are initiated should the cost
exceed the minimum charge. If you return a
unit under warranty, but it is not defective, the
minimum charge will apply.
5

Advertisement

loading

This manual is also suitable for:

Penberthy 2r-slPenberthy 2r-wPenberthy 2r-sPenberthy 2r-wl