1 - Description PS ES+ Thermal Stores are intended for storing and subsequent distribution of thermal energy from solid-fuel fired boilers, heat pumps, electric boilers etc. 230V or 3x230V/400V heating elements of 2-8.2 (12) kW output can be installed directly into the 6/4” tappings. Tanks are fitted with three side tappings, one top tapping and one tapping for sensor sheath.
Page 3
3 - Technical Data and Dimensions of PS ES+ Models ØDe ØDi │...
Code PS 600 ES+ PS 900 ES+ PS 1100 ES+ Thermal store Tank code 15527 15530 15956 Insulation code (accessor.) 16333 16340 16348 Application Storage and subsequent distribution of thermal energy from solid-fuel boilers, heat pumps or other heat sources. Energy efficiency data (as per EC Regulation No.
After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heating system using a suitable cleaning agent, e.g. MR-501/R or a similar one offered by Regulus. Anti-corrosion protective liquid for heating circuits should be also used, e.g. MR-501/F.
6 - Installing Insulation on the Tank Product description Fleece insulation with PU leather surface, zippered. Warning Insulation installation shall be done in two or three persons, depending on its size. The zippered, PU leather surface coated fleece insulation must not be installed at temperatures below 20 °C. If this cannot be avoided, the insulation shall be pre-warmed in another room to at least 20 °C.