5 Examples of Assigning Connection Points ................... 6 Installation and Commissioning ....................7 Tank Insulation ..........................8 Maintenance, Replacement of Magnesium Anode Bar ..............9 Disposal ............................10 Warranty ............................REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
2× lateral with G 5/4“ inner thread, to the heating coil 2× lateral with G 5/4“ inner thread (RBC 200, RBC 300 and RBC 400 with G 1“ inner thread, RBC 1500 - 3000 with G 2“ inner thread) for cold water inlet and hot water outlet 2×...
Max. working temperature - heat exchanger ............110 °C Max. working pressure - tank ................10 bar Max. working pressure - heat exchanger ............. 10 bar DHW heating ∆t =35 °C (80/60 - 10/45) - coil ............f REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
DHW auxiliary heating. Hot water temperature should be set to 60-65 °C. This temperature guarantees the best operation and at the same time, it prevents formation of Legionella bacteria. REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
3-way z.v. cold water Example II. A larger solar surface - enlarged Enlarged solar heat transfer surface area. heat transfer surface area bb bbb recirculation cold water 3-way z.v Pool REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
Page 7
Table of limit values for total dissolved solids in hot water Description Total dissolved solids (TDS) Chlorides Max. value 6.5 - 9.5 600 mg/l 40 mg/l 100 mg/l 20 mg/l 200 mg/l 0,2 mg/l REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
In order to prevent water loss, an expansion tank should be installed at the cold water inlet as well (8 l volume for RBC 200, 12 l volume for RBC 300 and 400, 18 l volume for RBC 500, 24 l volume for RBC 750, 35 l volume for RBC 1000, 60 l volume for RBC 1500, 80 l volume for RBC 2000, 100 l volume for...
○ defects caused by mechanical damage to the product, ○ defects caused by tampering or incompetent repair. REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
This product is covered by warranty according to the conditions described in this Manual and according to the Warranty Certificate. A Warranty Certificate is an integral part of the supply. Tank transport or storing in a hori- zontal position is considered a warranty violation! REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
Page 11
REGULUS - RBC Hot Water Storage Tanks - www.regulus.eu │...
Need help?
Do you have a question about the RBC 300 and is the answer not in the manual?
Questions and answers