8.2
Read Only Parameters
Sym.
Parameter Description
Main Board Firmware Release
Water softener board software version. (only for dishwashers with
incorporated continuous water softener).
Active column: indicates through which of the two continuous
water softener columns boiler filling is being carried out: 0 = col-
umn A and 1 = column B (only for dishwashers with incorporated
continuous water softener).
When
After maintenance, to clear
When
parameter is 3.
After maintenance (see alarm codes document), insert 0 to ena-
ble the machine.
This alarm appears in case of malfunctioning in the continuous
water softener. To facilitate fault-finding, see par. 13.3 ALARMS
THAT DON'T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER.
8.3
Communication and HACCP Parameters
Sym.
Parameter Description
Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1)
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is nec-
9 = Dishwashers with incorporated continuous water softener
16 = HACCP printer (8N1)
32 = MODEM GSM
33 = MODEM GSM
48 = Hyper Terminal (8N1)
Address.
This parameter specifies the address of the appliance into the
'HACCP_network'.
Works only if 'HACCP network' is selected (see above parameter).
Print parameter table.
HACCP 'Basic' (printer)
Boiler temperature: high limit.
HACCP 'Basic' (printer)
Boiler temperature: gap below high limit.
HACCP 'Basic' (printer)
Tank temperature: high limit.
HACCP 'Basic' (printer)
Tank temperature: gap below high limit.
DOC. NO. 5956.65J.00
EFS - Dishwashing Systems Platform
Electrolux Professional
message appears, the parameter value becomes 3.
message, insert 0.
alarm appears, the machine is frozen and this
essary)
(DAAS 8N1)
(DAAS 8E1)
Factory
Unit
Min
Max
Default
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Factory
Unit
Min
Max
Default
-
0
63
-
0
255
-
0
1
[°C]
45
95
[°C]
0
20
[°C]
35
75
[°C]
0
20
-
-
-
-
-
-
1
1
1
90
10
68
10
P. 17 / 174