To modify thresholds do the following:
•
Switch OFF and switch ON the dishwasher;
•
Enter into the FACTORY SETTING mode by pressing and hold down ON/OFF and CYCLE_2 keys for at
least five seconds (Figure 33);
•
Press CYCLE INFINITE. The display shows alternatively the symbol
sponding value
•
Use CYCLE_1 key to decrease the value and CYCLE_2 key to increase (Figure 35);
•
Press CYCLE INFITE key to confirm. The display shows the next parameter (Figure 36) and the corre-
sponding value (Figure 37);
•
In the same way is possible to change the other parameters; when finished switch OFF and switch ON.
FAC
Fig. 33 Factory setting
mode.
2
Fig. 37 Change value &
Store
At the end the display will show again
cycle duration (see paragraph 7 CYCLE SETTING).
).
FAC
Fig. 40 Factory setting
mode
DOC. NO. 5956.65J.00
EFS - Dishwashing Systems Platform
Electrolux Professional
(Figure 35);
°
bt
C
Fig. 34 Boiler temp.
threshold
bHi
Fig. 38 Tank temp. High
limit.
FAC
Fig. 41 Next Family
76
Fig. 35 Change value &
Store
96
Fig. 39 Change value &
Store.
and by pressing CYCLE_2 key (Fig. 41) is possible to change
Cy1
Fig. 42 Cycle 1 Family:
ENTER.
(Figure 34) and the corre-
btH
Fig. 36 Boiler Temp
Hysteresis
bLo
P. 12 / 174