Other Parameters; Drain/Cleaning Cycle Parameters; Dishwashing Parameters - Electrolux EPPWELGM5 Service Manual

Table of Contents

Advertisement


7.5

Drain/Cleaning Cycle Parameters

Sym.
Parameter Description

Initial Drain Phase Duration

Final Drain Phase Duration

Drain without cleaning cycle
Number of wash cycles possible between one drain cycle and the

next
Indicates the maximum permissible delay between drain cycle

start and the reaching of a tank level below the work level. If the
set delay is exceeded, alarm B1 occurs.

8 OTHER PARAMETERS


8.1

Dishwashing Parameters

Sym.
Parameter Description

Initial Pause before start washing (for ALL cycles)

Delay for the 2

Active a drain phase at the end of washing phase.
Duration of pause after rinse cycle (valid for dishwashers with

door/hood lock device) [See par. 9.2 MEDICAL LINE DISH-
WASHER WITH DOOR/HOOD LOCK DEVICE].
Celsius/Fahrenheit selection

0 = Celsius
1 = Fahrenheit
Rinse Temperature Display.
Enable rinse temperature probe (if installed).

0 = during rinse phase the display shows boiler temperature;
1 = during rinse phase the display shows rinse temperature;
Pulse Per Litre.

This parameter must be settled in according to flow meter
installed [present up to software version 3.12].
Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor – par. 9.3

DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION)

[
Enable mode Thermal Label: if set to 1 it enables the mode and

disables the "endless cycle" button

Boiler temperature in mode Thermal Label.

Tank temperature in mode Thermal Label.

Tank temperature hysteresis in mode Thermal Label.

Pressure sensor threshold 1 [present up to software version 2.11].

Pressure sensor histeresis 1 [present up to software version 2.11].

Pressure sensor threshold 2 [present up to software version 2.11].

Pressure sensor histeresis 2 [present up to software version 2.11].


Note:
,
doesn't correspond to a physical quantity.
DOC. NO. 5956.65J.00
EFS - Dishwashing Systems Platform
Electrolux Professional
nd
wash pump (PW only)
]


,
,
parameters emulates a two levels pressure switch, keep in mind that value
Unit
Min
Max
[s]
0
240
[s]
0
240
-
0
1
[wash
0
200
cycles]
[s] x 10
0
100
Factory
Unit
Min
Max
Default
[s]
0
10
[s]
0
10
[s]
0
40
[s]
0
60
-
0
1
-
0
1
[p/l]
0
255
-
0
5
-
0
1
[°C]
45
97
[°C]
40
90
[°C]
0
30
-
0
255
-
0
255
-
0
255
-
0
255
Factory
Default
40
80
0
0
18
0
3
0
0
0
0
0
5
0
86
75
2
140
50
140
50
P. 16 / 174