Table 6- 18
Byte
0
1
2
3 ... 4
5
6.3.2.2
syscmd_get_info
Max. reader response time: 50 ms
Table 6- 19
Byte
0
1
2
3 ... 4
5
Table 6- 20
Byte
0
1
2
3
4
5 ... 45
46
SIMATIC RF1000
Operating Instructions, 02/2019, C79000-G8976-C432-04
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x00
DevCode
0x03
CmdCode
0x00
Parameter length (0 bytes)
0xXX
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x00
DevCode
0x04
CmdCode
0x00
Parameter length (0 bytes)
0xXX
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x00
DevCode
0x04
CmdCode
0x29
Parameter length (e.g. 41 bytes)
0x00
0x01 ...
Firmware version of the reader, date of manufacture as ASCII value
Example:
1100 IDE Z 1.02.00 09/18/18 43025112
0xXX
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
6.3 Programming via the RS232 interface
Programming
33