6.2.1.15

Return values

The following table contains a list of the possible values that the reader can return for the
various functions.
Value
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
SIMATIC RF1000
Operating Instructions, 02/2019, C79000-G8976-C432-04
Variable
BRP_OK
BRP_ERR_STATUS
BRP_ERR_BUSY
BRP_ERR_IDLE
BRP_ERR_TIMEOUT
BRP_ERR_CORRUPTED_FRAME
BRP_ERR_UNEXPECTED_FRAME
BRP_ERR_GENERAL_IO
BRP_ERR_BUFFER_OVERFLOW
BRP_ERR_NO_MORE_HANDLES
BRP_ERR_INSUFFICIENT_MEM
BRP_ERR_WRONG_HANDLE
BRP_ERR_WRONG_PARAMETERS
6.2 Programming via USB interface
Description
No error has occurred
The reader has returned a status code that is ≠ "0".
The reader is currently processing a function.
The reader is waiting for a function.
The response time has been exceeded.
A bad frame was detected.
An unexpected frame was detected.
The underlying serial port has caused an error.
The reader sent more data than expected.
There is no free session key.
There is not enough memory to generate a new
session key.
The specified session key does not exist.
The parameters of a function are incorrect.