Using the Alarm List/History Function

3-8

Using the Alarm List/History Function

3-8-1 How to Use the Alarm List/History

Confirming during Operation as an Element
Setting
Downloaded from
Elcodis.com
electronic components distributor
This section describes how to use the alarm list and the alarm history which
monitor the status of bits in the host and, if a bit status changes to 1 (ON), display
the corresponding message and the image/library data.
The alarm list/history can be checked using the System Menu of the PT. It is also
possible to check them during operation by registering them to the screen as an
element (alarm list can only be used as an element.).
The Support Tool can read out the alarm history record data stored to the PT to
the host as a text file. For the procedure for reading the alarm history record data,
refer to the NT-series Support Tool Ver. 4.1 for Windows Operation Manual .
An alarm list can only be displayed as an element while an alarm history can be
displayed on a confirmation screen which is called from the System Menu as
well as displayed as an element.
The status of the bit to be monitored (alarm list) and the record of bit status transi-
tion (alarm history) can be confirmed while the PT is operating.
Alarm List
Message (character string table No. 32)
set for bit memory table No. 14
Character string table No. 32
Image/library
data 113C
When the message displayed is pressed, the image/library
data (113C) set for bit memory table No. 14 is displayed.
Alarm History
Message (character string table No. 13)
set for bit memory table No. 24
Character string table No. 13
Character string table No. 12
Image/library
data 102B
When the upper message displayed is pressed, the image/library
data (102B) set for bit memory table No. 13 is displayed.
When creating a screen using the Support Tool, set the following.
Bit Memory Table
Set as shown below for the number of bits in the host to be monitored (for infor-
mation not indicated below, set as needed.).
• PC Address:
Bits in the host to be monitored
• Function:
Alarm
• History:
• For alarm list:
• For alarm history:
No.13
Character string table No. 50
Image/library data 1002
Character string table No. 32
No.14
Image/library data 113C
No.15
Character string table No. 54
Image/library data 1125
Character string table No. 11
No. 22
Image/library data 005F
No. 23
Character string table No. 12
Image/library data 102A
Character string table No. 13
Image/library data 102B
No. 24
Check mark set or no check mark
Check mark set
Section
3-8
Bit
HOST
A000000
0
←1(ON)
1
L001003
0
D010015
Recorded data
Bit memory table No. 24
97/12/04 11:19:20
Bit memory table No. 23
97/12/04 11:25:12
337