Daikin VRSIII-S Series Technical Data Manual
Daikin VRSIII-S Series Technical Data Manual

Daikin VRSIII-S Series Technical Data Manual

Concealed ceiling unit

Advertisement

EEDEN08-204
technical data
Concealed ceiling unit
FXMQ-PVE
2e

Advertisement

Table of Contents
loading

Summary of Contents for Daikin VRSIII-S Series

  • Page 1 EEDEN08-204 technical data Concealed ceiling unit FXMQ-PVE...
  • Page 2: Table Of Contents

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE TABLE OF CONTENTS FXMQ-PVE Specifications ............2 Technical Specifications .
  • Page 3: Specifications

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Specifications U n i l e d t e m o o r c e a Q - P S y s I n d V R V C o n F X M 1-1 TECHNICAL SPECIFICATIONS FXMQ40PVE...
  • Page 4: Electrical Specifications

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Specifications 1-2 ELECTRICAL SPECIFICATIONS FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE Power Supply Name Phase Frequency 50/60 Voltage 220-240/220 Current Minimum circuit amps (MCA) Maximum fuse amps (MFA) A Full load amps (FLA) Voltage range Minimum -10%...
  • Page 5: Safety Device Settings

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Safety device settings FXMQ-P Safety devices PC boad fuse 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A FXMQ-PVE PC boad fuse (Fan driver) 250V 5A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A...
  • Page 6: Control Systems

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Control systems FXMQ-P Type FXMQ~PVE Item BRC4C65 Wireless Remote control BRC4C66 Wired BRC1D52 Simplified remote control BRC2C51 Remote control for hotel use BRC3A61 Adaptor for wiring KRP1C64 Wiring adaptor for electrical appendices (1) KRP2A61 Wiring adaptor for electrical appendices (2) KRP4AA51...
  • Page 7: Capacity Tables

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Capacity tables 5 - 1 Cooling capacity tables FXMQ-P TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Unit Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB air temp. size capacity 20.0DB...
  • Page 8 • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Capacity tables 5 - 1 Cooling capacity tables FXMQ-P TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Unit Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB air temp. size capacity 20.0DB...
  • Page 9: Heating Capacity Tables

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Capacity tables 5 - 2 Heating capacity tables FXMQ-P TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Nominal Outdoor air temp. Unit size 16.0 18.0 20.0 21.0 22.0 24.0 capacity °CDB °CWB...
  • Page 10 • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Capacity tables 5 - 2 Heating capacity tables FXMQ-P TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Nominal Outdoor air temp. Unit size 16.0 18.0 20.0 21.0 22.0 24.0 capacity °CDB °CWB...
  • Page 11: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXMQ40P NOTES Location of MANUFACTURE’S LABEL: Control box Space for Service Works surface According to any one of below 1) - 3), secure a space for service works, such Mount the air filter at the suction side.
  • Page 12 • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXMQ100,125P NOTES Location of MANUFACTURE’S LABEL: Space for Service Works Control box surface According to any one of below 1) - 3), secure a space for service works, such Mount the air filter at the suction side.
  • Page 13 • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXMQ100,125P FXMQ-P NOTES • REMOTE CONTROL DIMENSIONS • RECEIVER DETAIL Location of MANUFACTURE’S LABEL: Space for Service Works Transmitting part Control box surface According to any one of below 1) - 3), secure a space for service works, such Mount the air filter at the suction side.
  • Page 14: Centre Of Gravity

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Dimensional drawing & centre of gravity 6 - 2 Centre of gravity FXMQ-P MODEL NAME FXMQ40P FXMQ50•63•80P FXMQ100•125P 4D060438 ® • VRV Systems • Indoor Units...
  • Page 15: Piping Diagram

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Piping diagram FXMQ-P Gas pipe connection port Heat exchanger Liquid pipe connection port Filter Filter Electronic expansion valve 4D034245C ® • VRV Systems • Indoor Units...
  • Page 16: Wiring Diagram

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Wiring diagram 8 - 1 Wiring diagram FXMQ-P WIRING DIAGRAM Power supply Input from outside Note 2. Transmission wiring central remote For FXMQ50PVE • 63PVE • 80PVE • 100PVE • 125PVE control Note 1.
  • Page 17: Sound Data

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Sound data 9 - 1 Sound pressure spectrum FXMQ40P FXMQ50P Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 4D060446 4D060428 NOTES...
  • Page 18 • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Sound data 9 - 1 Sound pressure spectrum FXMQ100P FXMQ125P Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 4D060448 4D060449 NOTES...
  • Page 19: Fan Characteristics

    • Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE Fan characteristics FXMQ40P FXMQ50P Fan characteristics Fan characteristics Fan characteristics Fan characteristics NOTES NOTES (For local setting of remote control) (For local setting of remote control) Range of available air flow rate in HH Range of available air flow rate in HH As for this machine, setting is possible As for this machine, setting is possible...
  • Page 20 The present publication is drawn up by way of information only and conditioning equipment, compressors and Quality Management System in accordance with the does not constitute an offer binding upon Daikin Europe N.V.. Daikin refrigerants has led to its close involvement in ISO9001 standard. ISO9001 pertains to quality Europe N.V.

Table of Contents