Daikin BEVQ71MVE Installation Manual
Daikin BEVQ71MVE Installation Manual

Daikin BEVQ71MVE Installation Manual

Vrv system inverter air conditioners
Hide thumbs Also See for BEVQ71MVE:

Advertisement

Quick Links

SYSTEM Inverter Air Conditioners
MODELS
BEV unit
BEVQ71MVE
BEVQ71MAVE
BEVQ100MVE
BEVQ100MAVE
BEVQ125MVE
BEVQ125MAVE
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER
ALGUNA DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.
INSTALLATION MANUAL
English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Daikin BEVQ71MVE

  • Page 1 INSTALLATION MANUAL English SYSTEM Inverter Air Conditioners Deutsch MODELS Français BEV unit BEVQ71MVE BEVQ71MAVE Español BEVQ100MVE BEVQ100MAVE BEVQ125MVE BEVQ125MAVE Italiano ΕλληνικÜ READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2 3P109591-1E...
  • Page 3: Table Of Contents

    BEVQ71MVE BEVQ71MAVE BEVQ100MVE BEVQ100MAVE VRV SYSTEM Inverter Air Conditioners Installation manual BEVQ125MVE BEVQ125MAVE CONTENTS 1 SAFETY PRECAUTIONS....................1 2 BEFORE INSTALLATION ....................3 3 SELECTING INSTALLATION SITE................4 4 PREPARATIONS BEFORE INSTALLATION ..............6 5 BEV UNIT INSTALLATION ....................7 6 REFRIGERANT PIPING WORK ..................7 7 ELECTRIC WIRING WORK ..................10...
  • Page 4 • Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this installation manual. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire. •...
  • Page 5: Before Installation

    2. BEFORE INSTALLATION • When moving the unit while removing it from the carton box, be sure to lift it by holding on to the two lifting lugs without exerting any pressure on other parts, especially, the refrigerant piping. • Be sure to check the type of R410A refrigerant to be used before installing the unit. (Using an incorrect refrigerant will prevent normal operation of the unit.) •...
  • Page 6: Selecting Installation Site

    FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED. a. Items to be checked after completion of work Items to be checked If not properly done, what is likely to occur Check Are the indoor and outdoor and BEV unit fixed firmly? The units may drop, vibrate or make noise.
  • Page 7 〈〈When hanging the unit from the ceiling〉〉 Install so that the control box lid is facing down. Direction of the gas piping connection piping Horizontal position Maintenance hole 450 or more Take the gas piping thermistor out from above. Be sure to create a maintenance hole the size shown in the figure above.
  • Page 8: Preparations Before Installation

    4. PREPARATIONS BEFORE INSTALLATION 〈〈When hanging the unit from the ceiling〉〉 (1) Check the relative locations of ceiling hole, unit, and hanging bolts. <Example of installation> Ceiling slab (Suspension bolt pitch) Anchor Long nut or turnbuckle Suspension bolt BEV unit proper Note: All the above parts are field supplied.
  • Page 9: Bev Unit Installation

    5. BEV UNIT INSTALLATION • Use only accessories and parts which are of the designated specification when installing. 〈〈When hanging the unit from the ceiling〉〉 (1) Temporarily install the BEV unit. • Mount the hanging fittings to hanging bolts. Secure the Nut (field supplied) hanging fittings on the top and the bottom with nuts (M8, field supplied) and washers (M8: Outside diameter size...
  • Page 10 Table 1 Pipe size Tightening torque Flare dimension A (mm) Flare shape φ 9.5 (3/8”) 32.7 – 39.9N · m 12.8 – 13.2 R0.4-0.8 φ 15.9 (5/8”) 61.8 – 75.4N · m 19.3 – 19.7 NOTE The flare nuts used must be those included with the main body. Torque wrench Ester oil or ether oil Spanner...
  • Page 11 Cut any extra line off Insulation for after tightening it. Liquid piping fitting (4) (accessory) Insulation for fitting (3) (accessory) Cut any extra line off Flare nut after tightening it. Clamp (2) Piping union (accessory) Clamp (2) Flare nut (accessory) Flare nut Piping union Cut any extra line off...
  • Page 12: Electric Wiring Work

    Piping connection procedure • Make sure the length of the refrigerant piping between the BEV unit and the indoor unit is no more than 5m and that the difference in height is at least 4m. (1) Connection example for the indoor unit •...
  • Page 13 • One BEV unit is connected to one indoor unit. Mark each indoor unit and BEV unit as unit A, unit B..., and be sure the terminal block wiring to the outdoor unit and BS unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit and BEV unit are mismatched, the system may cause a mal- function.
  • Page 14: Wiring Example And How To Set The Remote Controller

    8. WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER 8-1 HOW TO CONNECT WIRINGS • Connect the piping only after finishing the refrigerant piping work. • Make sure all power supply is shut down to the unit first. • As shown in the Fig. 16, loosen the two screws in the control box lid, remove it, and do the wiring work. •...
  • Page 15 CAUTION • When clamping wiring, use the included clamping material to prevent outside presure being exerted on the wiring connections and clamp firmly. When doing the wiring, make sure the wiring is neat and does not cause the control box lid to stick up, then close the cover firmly. •...
  • Page 16 8-3 WIRING EXAMPLE • Fit the power supply wiring of each unit with a switch and fuse as shown in the drawing. COMPLETE SYSTEM EXAMPLE (3 systems) Power supply Power supply wiring Main switch Transmission wiring Switch Fuse BS unit (Only for Heat recovery system)
  • Page 17 2. For group control or use with 2 remote controllers Power supply 220-240V Outdoor unit 50Hz Control box IN/D OUT/D 220V 60Hz BEV unit B BEV unit A Most 1 2 3 1 2 3 1 2 3 downstream BEV unit Most 1 2 3 1 2 3...
  • Page 18: How To Attach The Nameplate

    8-4 DEFAULT SETTINGS 1. Once piping work is completed, conduct the following settings as needed. (1) When connecting the BEV unit to the BS unit in the heating/cooling free sys- tem, turn the SS1 on the A1P to M (Main) for only one of the BEV units con- nected to the remote controller on which heating/cooling switching is made Fig.