Daikin FXUQ71MV1 Installation Manual
Daikin FXUQ71MV1 Installation Manual

Daikin FXUQ71MV1 Installation Manual

Vrv system inverter
Hide thumbs Also See for FXUQ71MV1:

Advertisement

SYSTEM Inverter Air Conditioners
MODELS
(Ceiling suspended Cassette type)
FXUQ71MV1
FXUQ71MAV1
FXUQ100MV1
FXUQ100MAV1
FXUQ125MV1
FXUQ125MAV1
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER
ALGUNA DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.

INSTALLATION MANUAL

English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Рóссêий

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXUQ71MV1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FXUQ71MV1

  • Page 1: Installation Manual

    INSTALLATION MANUAL English SYSTEM Inverter Air Conditioners Deutsch MODELS Français (Ceiling suspended Cassette type) FXUQ71MV1 FXUQ71MAV1 Español FXUQ100MV1 FXUQ100MAV1 FXUQ125MV1 FXUQ125MAV1 Italiano ΕλληνικÜ READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2 3P109591-1E...
  • Page 3: Table Of Contents

    FXUQ71MV1 FXUQ71MAV1 FXUQ100MV1 FXUQ100MAV1 VRV SYSTEM Inverter Air Conditioners Installation manual FXUQ125MV1 FXUQ125MAV1 CONTENTS • Install the air conditioner on a foundation strong enough to withstand the weight of the unit. 1. SAFETY PRECAUTIONS..........1 A foundation of insufficient strength may result in the equip- 2.
  • Page 4: Before Installation

    • Do not install the air conditioner in the following locations: ACCESSORIES 1. Where there is a high concentration of mineral oil spray or Check the following accessories are included with the unit. vapour (e.g. a kitchen). 3) Washers for Name 1) Drain hose 2) Metal clamp...
  • Page 5: Selecting Installation Site And Air Flow Direction

    FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE • Where nothing blocks air passage. • Where condensate can be properly drained. DURING CONSTRUCTION AND CHECK AFTER • Where the ceiling is strong enough to bear the indoor unit INSTALLATION IS FINISHED. weight.
  • Page 6: Preparations Before Installation

    Air flow Ceiling slab direction Anchor 4-way air 3-way air 3-way air discharge discharge discharge Long nut or turnbuckle False ceiling Optional parts required (Back-to-back blocking pad kit) Suspension bolt (length: mm) Fig. 3 NOTE • All the above parts are field supplied. (Use either a M8-M10 size bolt) 2-way air 2-way air...
  • Page 7 NOTE • IIlustration seen from ceiling 790∗∗∗ Shutter Piping area Air discharge (Indicates drain pan.) Shutter Rightward running drain piping shown above Piping area When shipped from factory Liquid piping Gas piping Drain hose Moderate connection (VP20) flow rate (length: mm) Fig.
  • Page 8 4. After installing the blocking pads, attach the center retainer for blocking pad and the top decorative plate. (Refer to Fig. 13) Air intake grille Cornercover (×4) Center retainer Fig. 10 for blocking pad (15) Insert (accessory) Hold the indoor unit by the here.
  • Page 9: Indoor Unit Installation

    Moderate flow rate Moderate flow rate Moderate Moderate flow rate flow rate Blocking pad Blocking pad Moderate flow rate Moderate flow rate Blocking pad Blocking pad Moderate flow rate Moderate Fig. 16 flow rate [CEILING HEIGHT] The indoor unit may be installed on ceilings up to 3.8 m in height. Fig.
  • Page 10: Refrigerant Piping Work

    CAUTION Securing the washer • Use a pipe cutter and flare suitable for the type of refrig- Piping area erant. • Apply ester oil or ether oil around the flare section before connecting. • To prevent dust, moisture or other foreign matter from Insert below infiltrating the tube, either pinch the end or cover it with washer.
  • Page 11: Drain Piping Work

    Table 2 Since there exists a possibility that small animals and insects might get inside the indoor unit, attach the wir- Flare Pipe size Tightening torque Flare ing through covers and make sure there are no gaps in dimensions A (mm) the through holes by applying putty or insulation (field φ9.5(3/8”) supplied).
  • Page 12 Drain hose (1) (For VP20 connection) Metal clamp (2) Metal clamp (2) Large Drain piping (accessory) sealing pad (8) (accessory) (field supplied) (accessory) Ceiling slab (accessory) 1 - 1.5 m Hanger VP20 bracket Elbow (10) VP20 Large sealing pad (8) (accessory) Drain hose (1) Tape ≤4mm...
  • Page 13: Electric Wiring Work

    [Caution] • One BEV unit is connected to one indoor unit. Mark each Drain piping connections indoor unit and BEV unit as unit A, unit B..., and be sure the • Do not connect the drain piping directly to sewage pipes that terminal block wiring to the outdoor unit and BS unit are smell of ammonia.
  • Page 14 WIRING EXAMPLE CAUTION • Fit the power supply wiring of each unit with a switch and • When clamping wiring, use the included clamping material fuse as shown in the drawing. to prevent outside pressure being exerted on the wiring con- COMPLETE SYSTEM EXAMPLE (3 systems) nections and clamp firmly.
  • Page 15: Installation Of Corner Cover And Air Intake Grille

    3. When including BS unit <Caution> • If using group control and two remote controllers at the Power supply Power supply same time, connect remote controller 2 (SUB) to the indoor Outdoor unit unit which is at the end of the crossover wiring (P ).
  • Page 16: Field Settings

    10. FIELD SETTINGS 10-5 Setting air filter sign • Remote controllers are equiped with liquid crystal display air 10-1 Make sure the control box lids are closed on filer signs to display the time to clean air filters. the indoor and BEV and outdoor units. •...
  • Page 17 3P086156-10X EM03A117B (0905)

This manual is also suitable for:

Fxuq100mv1Fxuq125mv1Fxuq71mav1Fxuq125mav1Fxuq100mav1

Table of Contents