  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Deutsch MODELS Français (Ceiling suspended Cassette type) FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 Español FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 Italiano Ελληνικά Nederlands Portugues Русский...
  • Page 2 Funktionen der Schalter und Anzeigen auf der Fernbedi- enung. Nous vous remercions pour votre acquisition de ce clima- Wij danken u voor de aankoop van deze Daikin aircondi- tiseur Daikin. tioner. Lees deze bedrijfshandleiding aandachtig door Lisez attentivement ce manuel avant d’utiliser le climati- voordat u de airconditioner gebruikt.
  • Page 3: Disposal Requirements

    ■ DISPOSAL REQUIREMENTS ■ VORSCHRIFTEN ZUR ENTSORGUNG ■ INSTRUCTIONS D’ÉLIMINATION ■ REQUISITOS PARA LA ELIMINACIÓN ■ SPECIFICHE DI SMALTIMENTO ■ ΠΡΟΫΠΟΘΕΣΕΙΣ ΑΠΟΡΡΙΨΗΣ ■ VEREISTEN VOOR HET OPRUIMEN ■ REQUISITOS PARA A ELIMINAÇÃO Disposal requirements Specifiche di smaltimento Your air conditioning product is marked with this symbol. This means that Il climatizzatore è...
  • Page 4: Table Of Contents

    : 1975 NOTE GWP = global warming potential • Contact your Daikin dealer in case of changing Periodical inspections for refrigerant leaks may be the combination or setting of group control and required depending on European or local legislation.
  • Page 5: Safety Considerations

    Inlet air Discharged air If your installation has a customized control system, Air outlet ask your Daikin dealer for the operation that corre- sponds to your system. Air flow flap (at air outlet) Refrigerant piping, connection electric wire • Heat pump type, Heat recovery type...
  • Page 6 • The precautions described below are WARN- Ask your dealer to move and reinstall the air conditioner. ING and CAUTION. These are very important Incomplete installation may result in a water leak- precautions concerning safety. Be sure to age, electric shock, and fire. observe all of them without fail.
  • Page 7: Operation Range

    Do not place items that might be damaged by Avoid placing the remote controller in a spot water under the indoor unit. splashed with water. Water may condensate and drip if the humidity Water coming inside the machine may cause an reaches 80% or if the drain exit gets clogged.
  • Page 8: Installation Site

    • Operating procedure varies with heat pump type d. Where there are considerable voltage fluctua- and cooling only type. Contact your Daikin dealer tions such as a factory or plant to confirm your system type. e. Vehicles and vessels •...
  • Page 9: Optimum Operation

    Press the AIR FLOW DIRECTION ADJUST but- • Turn off the main power supply switch when it is ton to select the air direction as shown below. not used for long periods of time. When the main power switch is turned on, some watts of electricity The AIR FLOW FLAP display is being used even if the system is not operating.
  • Page 10 1. Open the suction grille. 5. Close the suction grille. Slide both knobs simultaneously as shown and Refer to item No. 1. then pull them downward. 6. After turning on the power, press AIR FILTER (Do the same procedure for closing.) CLEANING TIME ICON RESET button.
  • Page 11: Not Malfunction Of The Air Conditioner

    It is necessary to clean the • Read the operation manual attached to the inside of the indoor unit. Ask your Daikin dealer for remote controller. details on cleaning the unit. This operation Cut off the power supply.
  • Page 12: Trouble Shooting

    MALFUNCTION CODE Expansion and contraction of plastic parts caused Measure: Notify your Daikin dealer and inform by temperature change makes this noise. him/her of the display. IV. DUST FROM THE UNITS II. If the system does not properly operate •...
  • Page 13 2. If the system stops operating after operating the system. • Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles. Remove the obstacle and make it well-ventilated. • Check if the air filter is clogged. Ask a qualified service person to clean the air filters (Refer to MAINTENANCE).
  • Page 14 3P177429-2D EM03A094F (0704) FS HT...