Fig. 4-4
3.
Insert the ribbon cable at connector X538 of
the "SSB"
Note:
The ribbon cable has a coding pin (pin 9) and
can only be inserted in the correct position in
the connector.
28
Fig. 4-5
4.
Insert "SSB" at connector X258 and tighten-up the
mounting bracket at X1.
Re-insert socket connector X18
Caution:
Do not remove the insulation foil on the solder side of
the "SSB"! It is used to insulate the line supply voltage
which is available at fuse F1 of the power supply.