Siemens SIMOVERT Masterdrives SSB Operating Instructions Manual page 27

Safe stop board
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
02.2000
♦ Assembly of construction types E ... G (H)
The "SSB" board is inserted in power supply connector X258. The ribbon cable to the electronics box must then
be attached to connector X538 on the "SSB". The mounting position of the power supply is shown in Fig. 2-1 or
Fig. 2-2 .
For type E, the DC link battery can be removed so that it is easier to access connector X258 of the power supply.
6SE7090-0XX84-1HK0
476 479.9000.00
Fig. 4-2
1.
Bolt the mounting bracket to "SSB"
Siemens AG 6SE7080-0AX87-1JB0
Safe Stop Board
Operating Instructions
C
A
B
Fig. 4-3
2.
Power-down SIMOVERT MASTERDRIVES!
For 230 V AC DC units
do not forget the fan power supply
check that the DC link is discharged!
A) Remove socket connector X18
B) Remove the ribbon cable from connector
X258
C) Remove the bolt at X1
27