WARNING! ENSURE PUMP IS ISOLATED FROM
ELECTRICITY AND WATER SUPPLY. IF IN
DOUBT CONSULT A COMPETENT
TRADESMAN.
Pump should be serviced in horizontal
position with couples disconnected and water
and electricity supply isolated.
DO NOT RUN PUMP DRY. ALLOW WATER TO
FILL PUMP TO LUBRICATE SEALS BEFORE
STARTING. CHECK FOR LEAKS DURING TEST
BEFORE BEING SATISFIED PUMP IS OK
Document SSI.10 December15. Issue 1
Salamander Pumps Shower Systems Limited
Unit 2c Colima Avenue, Enterprise Park West,
Sunderland, SR5 3XE
Telephone:
0191 516 2002
Facsimile:
0191 548 4445
Email: sales@salamanderpumps.co.uk
www.salamanderpumps.co.uk
PLEASE NOTE:
By using the parts included in this pack to repair your pump, you will
be invalidating any warranty you have on the pump.
Returns:
If you need to return this pack for any reason please ensure the
original packaging and these instructions leaflets are returned also.
If you have any questions or queries regarding this spares pack or
any other pump related questions please contact us.
UK:
Salamander Pumped Shower Systems Limited
Unit 2c, Colima Avenue Enterprise Park West
Sunderland SR5 3XE
Tel: 0191 516 2002
Email: tech@salamanderpumps.co.uk
Eire:
MTA agencies Ireland Fearn House,
Unit 4 Jamestown Business Park
Jamestown Road Finglas,
Dublin 11
Tel: +353 (0)1 864 3363
Email: service@mtagencies.ie
Instructions VIDEOLINK:
INTRODUCTION
CT HUXTRA/CT FORCEU/BathroomU
(All Universal Variants)
Tools required :
• PZ2 Screwdriver
• 7mm Deep Socket
• Long nose Pliers
• Snips
• 7 mm OE Spanner
• M6 Allen bit/Wrench
• 2mm Flat Screwdriver
Parts in Service kit:
• Float- PFLOAT(26) x 2
• NRV - CNRVPL01 (3) x 2
• Hall effect sensor HE - EHALLE05 (19) x 2
• Cable Tie- FCABLE01(22) x 2
• Interface -EPCBUN05 (5) x 1
• Vessel Washer - F washe06 - (25) x 1
• JB Lid Screw- FScrew11 - (8) x 3
• M6 x 20 SS Cap Screw -FBOLTM13- (21)x6
• M6 Spring Washer- FWASHE03 -(20) x 6
• O Ring 59.6mm x 2.4mm- SORING 17- (18) x 2
(Blue) EPDM
• Filter washers (30) x 2
• Rubber Flat washers (29) x 2

Advertisement

loading

Summary of Contents for Salamander Pumps CTFORCEU

  • Page 1 Instructions VIDEOLINK: Salamander Pumps Shower Systems Limited SKELECT07 ELECT & MECH INTRODUCTION Unit 2c Colima Avenue, Enterprise Park West, Sunderland, SR5 3XE Telephone: 0191 516 2002 CT HUXTRA/CT FORCEU/BathroomU Facsimile: 0191 548 4445 Email: sales@salamanderpumps.co.uk (All Universal Variants) www.salamanderpumps.co.uk Tools required : •...
  • Page 2 SKELECT07 SERVICE INSTRUCTIONS: 1. Remove Non Return Valve (NRV) (3 ) noticing its orientation using long nosed pliers and discard. 2. Remove float (26) noticing its orientation. Discard. 3. Remove pressure vessel(24) and vessel washer (25) 4. Remove Junction box (JB) box lid screws (8) using PZ2 driver and discard. 5.