Daily Startup; Daily Shutdown - Graco T2 Instructions Manual

2:1 ratio transfer pump
Hide thumbs Also See for T2:
Table of Contents

Advertisement

Daily Startup

1. Verify that the air needle valve is closed.
2. Connect the air line quick disconnect coupler to the
transfer pump
3. Turn on the main air supply.
4. Slowly open the air needle valve until the transfer
pump runs slowly.
5. Use the air needle valve to control the pump speed.
311882U
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed and could cause damage to the pump. If the
pump accelerates quickly or starts running too fast,
stop it immediately and check the fluid supply. If the
supply container is empty or air has been pumped
into the lines, refill the container and prime the pump
and the lines with fluid, or flush and leave it filled with
a compatible solvent. Be sure to eliminate all air from
the fluid system.
Do not attempt to operate pump unless it is securely
mounted in a drum.

Daily Shutdown

1. Disconnect air line coupler.
2. When air pressure is bled off, close the air line
needle valve.
Operation
NOTICE
15